Validation of a Monte Carlo Modelling Based Dosimetry of Extraoral Photobiomodulation
Rattachement africain : us, it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
An in vivo validation study was performed to confirm the accuracy of extraoral photobiomodulation therapy (PBMT) dosimetry determined by modelling. The Monte Carlo technique was utilized to calculate the fluence rate and absorbed power of light delivered through multi-layered tissue. Optical properties used during Monte Carlo simulations were taken from the literature. Morphological data of four study volunteers were acquired using magnetic resonance imaging (MRI) scans. Light emitting diode (LED) coupled to a power meter were utilized to measure transmitted power through each volunteer's cheek, in vivo. The transmitted power determined by Monte Carlo modelling was compared to the in vivo measurements to determine the accuracy of the simulations. Experimental and simulation results were in good agreement for all four subjects. The difference between the mean values of the measured transmission was within 12% from the respective transmission obtained using Monte Carlo simulations. The results of the study indicate that Monte Carlo modelling is a robust and reliable method for light dosimetry.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Validation of a Monte Carlo Modelling Based Dosimetry of Extraoral Photobiomodulation
- Date Crossref
- 26/11/2021
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Massachusetts Lowell Advanced Biophotonics Laboratory pays non établi dans la noticeUniversité ou école supérieure
-
Massachusetts General Hospital Department of Dermatology pays non établi dans la noticeÉtablissement de santé
-
Massachusetts Eye and Ear Infirmary pays non établi dans la noticeÉtablissement de santé
-
Harvard University pays non établi dans la noticeUniversité ou école supérieure
-
Texas A&M Health Science Center pays non établi dans la noticeUniversité ou école supérieure
-
University of Genoa Department of Surgical Science and Integrated Diagnostics pays non établi dans la noticeUniversité ou école supérieure
-
Brigham and Women's Hospital Department of Surgery pays non établi dans la noticeÉtablissement de santé
-
Dana-Farber/Boston Children's Cancer and Blood Disorders Center pays non établi dans la noticeÉtablissement de santé
-
Department of Radiology pays non établi dans la noticeInstitution
-
College of Medicine Texas A&M Health Science Center pays non établi dans la noticeUniversité ou école supérieure
-
THOR Photomedicine pays non établi dans la noticeInstitution
-
Biomodels LLC pays non établi dans la noticeInstitution
Advanced Biophotonics Laboratory — University of Massachusetts Lowell, Department of Dermatology — Massachusetts General Hospital et Massachusetts Eye and Ear Infirmary, avec 9 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.