Aller au contenu principal
2021 article

Efficacy and Safety of Taulinoplasty Compared with the Minimally Invasive Repair of Pectus Excavatum Approach to Correct Pectus Excavatum

5Citations signalées — pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Background: Minimally invasive repair of pectus excavatum (MIRPE) technique is the current most used surgical method for pectus excavatum (PE) correction. To avoid MIRPE-required invasion of the mediastinum or pleural cavity, we developed taulinoplasty approach as an alternative option for the reduction of the sunken chest. Materials and Methods: This is a single-center unblind nonrandomized prospective pilot study, involving 26 MIRPE and 23 taulinoplasty patients. The primary safety endpoint was the presence of surgical complications, and the primary efficacy endpoint was Haller index measured postoperatively in taulinoplasty patients. Secondary endpoints were intensive care unit (ICU) and hospital length of stay (LOS), duration of surgical procedure, and postoperative pain management. Chi-square, Mann–Whitney, or Student “ t ” tests were used for comparison as appropriate. Results: There were no difference in median age (14.5 and 14 years), Haller index (4.63 and 4.17), or comorbidities. MIRPE and taulinoplasty procedures showed no difference regarding major or minor surgical complications. The efficacy endpoint of taulinoplasty was measured 5.5 (1.5–12) months after the procedure, exhibiting a significant reduction in the Haller index [4.17 (3.7–4.7) at baseline and 3.7 (2.9–4.1) postoperatively, P = .03]. Taulinoplasty required less surgical time (60.4 ± 15.5 versus 70.7 ± 15.9 minutes, P < .01); shorter ICU and hospital LOS ( P < .01, respectively); and required fewer days of peridural, intravenous, and oral analgesia ( P < .01, respectively). Conclusions: In this pilot study, taulinoplasty technique was as safe as the MIRPE approach and effective for the correction of PE, reducing surgical time, ICU and hospital LOS, and achieving better postoperative pain control.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Efficacy and Safety of Taulinoplasty Compared with the Minimally Invasive Repair of Pectus Excavatum Approach to Correct Pectus Excavatum
Date Crossref
01/12/2021
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Pectus Deformity Diagnosis and TreatmentShoulder and Clavicle InjuriesReconstructive Surgery and Microvascular Techniques