Effectiveness of a Real-Time X-ray Dosimetry Monitor in Reducing Radiation Exposure in Coronary Procedures: The ESPRESSO-Raysafe Randomized Trial

4Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background—Several methods to reduce radiation exposure in the setting of coronary procedures are available on the market, and we previously showed that additional radiation shields reduce operator exposure during radial interventions. We set out to examine the efficacy of real-time personal dosimetry monitoring in a real-world setting of radial artery catheterization. Methods and Results—In an all-comer prospective, parallel study, consecutive coronary diagnostic and intervention procedures were performed with the use of standard radiation shield alone (control group) or with the addition of a real-time dosimetry monitoring system (Raysafe, Billdal, Sweden, monitoring group). The primary outcome was the difference in exposure of the primary operator among groups. Additional endpoints included patient, nurse, second operator exposure and fluoroscopy time. A total of 700 procedures were included in the analysis (n = 369 in the monitoring group). There were no differences among groups in patients’ body mass index (p = 0.232), type of procedure (intervention vs. diagnostic, p = 0.172), and patient sex (p = 0.784). Fluoroscopy time was shorter in the monitoring group (5.6 (5.1–6.2) min vs. 7.0 (6.1–7.7) min, p = 0.023). Radiation exposure was significantly lower in the monitoring group for the patient (135 (115–151) µSv vs. 208 (176–245) µSv, p < 0.0001) but not for the first operator (9 (7–11) µSv vs. 10 (8–11), p = 0.70) and the assistant (2 (1–2) µSv vs. 2 (1–2) µSv, p = 0.121). Conclusions—In clinical daily practice, the use of a real-time dosimetry monitoring device reduces patient radiation exposure and fluoroscopy time without an effect on operator radiation exposure.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Effectiveness of a Real-Time X-ray Dosimetry Monitor in Reducing Radiation Exposure in Coronary Procedures: The ESPRESSO-Raysafe Randomized Trial
Date Crossref
17/11/2021
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiation Dose and ImagingCardiac, Anesthesia and Surgical OutcomesAdvanced X-ray and CT Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.