Intraoperative transit time flow measurements during off‐pump coronary artery bypass surgery: The impact of coronary stenosis on competitive flow

8Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Combining preoperative angiography findings with intraoperative transit time flow measurements (TTFM) may improve patency of coronary artery bypass grafts. Nevertheless, graft flow might be impaired by native coronary flow based on the severity of stenoses, with inferior long-term outcomes. This study investigates the impact of left anterior descending artery (LAD) stenosis on competitive flow measured in left internal mammary artery (LIMA) grafts during off-pump coronary artery bypass grafting. METHODS: Fifty patients were included in this prospective single-center cohort study. LAD stenosis was assessed with quantitative coronary analysis (QCA) and stratified into three groups based on its severity. TTFM of LIMA grafts were performed with LAD open and temporarily occluded. Change in mean graft flow after LAD snaring was the primary endpoint. Secondary endpoints included further TTFM parameters, clinical outcomes, and competitive flow index (CFI), defined as the ratio of mean graft flow with open or closed LAD. RESULTS: Mean LAD stenosis as objectified with QCA was 58 ± 15%. Mean LIMA graft flow increased from 20 ml/min with open LAD to 30 ml/min with snared LAD (p < .001). TTFM cut-off values for graft patency improved in 26%-42% of patients after LAD occlusion. Median CFI was 0.66 (IQR: 0.56-0.82). Postoperative myocardial infarction occurred in 2.0% of patients, 120-day mortality was 0%, and 2-year mortality was 6.0%. CONCLUSIONS: Routine snaring of the LAD with CFI calculation during coronary artery bypass grafting is useful to detect significant competitive flow in LIMA grafts, potentially preventing unnecessary intraoperative graft revisions.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Intraoperative transit time flow measurements during off‐pump coronary artery bypass surgery: The impact of coronary stenosis on competitive flow
Date Crossref
21/10/2021
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac and Coronary Surgery TechniquesCoronary Interventions and DiagnosticsMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.