A deep‐learning‐based prediction model for the biodistribution of 90 Y microspheres in liver radioembolization
Rattachement africain : gr, fr, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background Radioembolization with 90 Y microspheres is a treatment approach for liver cancer. Currently, employed dosimetric calculations exhibit low accuracy, lacking consideration of individual patient, and tissue characteristics. Purpose The purpose of the present study was to employ deep learning (DL) algorithms to differentiate patterns of pretreatment distribution of 99m Tc‐macroaggregated albumin on SPECT/CT and post‐treatment distribution of 90 Y microspheres on PET/CT and to accurately predict how the 90 Y‐microspheres will be distributed in the liver tissue by radioembolization therapy. Methods Data for 19 patients with liver cancer (10 with hepatocellular carcinoma, 5 with intrahepatic cholangiocarcinoma, 4 with liver metastases) who underwent radioembolization with 90 Y microspheres were used for the DL training. We developed a 3D voxel‐based variation of the Pix2Pix model, which is a special type of conditional GANs designed to perform image‐to‐image translation. SPECT and CT scans along with the clinical target volume for each patient were used as inputs, as were their corresponding post‐treatment PET scans. The real and predicted absorbed PET doses for the tumor and the whole liver area were compared. Our model was evaluated using the leave‐one‐out method, and the dose calculations were measured using a tissue‐specific dose voxel kernel. Results The comparison of the real and predicted PET/CT scans showed an average absorbed dose difference of 5.42% ± 19.31% and 0.44% ± 1.64% for the tumor and the liver area, respectively. The average absorbed dose differences were 7.98 ± 31.39 Gy and 0.03 ± 0.25 Gy for the tumor and the non‐tumor liver parenchyma, respectively. Our model had a general tendency to underpredict the dosimetric results; the largest differences were noticed in one case, where the model underestimated the dose to the tumor area by 56.75% or 72.82 Gy. Conclusions The proposed deep‐learning‐based pretreatment planning method for liver radioembolization accurately predicted 90 Y microsphere biodistribution. Its combination with a rapid and accurate 3D dosimetry method will render it clinically suitable and could improve patient‐specific pretreatment planning.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- A deep‐learning‐based prediction model for the biodistribution of <sup>90</sup> Y microspheres in liver radioembolization
- Date Crossref
- 21/10/2021
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.