Development of a Portable Method for Serum Lithium Measurement Based on Low-Cost Miniaturized Ultrasonic Nebulization Coupled with Atmospheric-Pressure Air-Sustained Discharge
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
An accurate, rapid but cheap, and portable method for monitoring of serum lithium (Li) is highly desirable for mental patients who take Li medicine for treatment. Conventional techniques are usually bulky, costly, and cannot provide on-site real-time measurements. Herein, a miniaturized, reliable, cost-effective, and portable optical emission method for rapid and sensitive determination of serum Li was developed based on a combination of miniaturized ultrasonic nebulization (MUN) and a low-power (≈22 W) atmospheric-pressure air-sustained discharge (APAD) excitation source. The proposed method eliminates the use of any compressed gas or pump and can achieve serum Li detection within 40 s with low sample consumption (less than 20 μL serum). Except for dilution with water, no extra treatment is needed for serum Li analysis by MUN-APAD-OES. In addition, it offers a significant advantage of good tolerance to the coexisting high concentration of Na, K, Ca, and Mg, which is in contrast with the obvious matrix effect encountered in conventional inductively coupled plasma optical emission spectrometry (ICP-OES). Different operating parameters affecting the performance of MUN-APAD-OES were evaluated. Under optimized conditions, the detection limit of Li (670.8 nm) was calculated to be 0.6 μg L –1 (6 μg L –1 in serum). Finally, the accuracy of the proposed method was validated by the analysis of two certified reference materials (Seronorm serum L-1 and L-2 RUO), six real human serum samples, and eight real animal serum samples. All of the results indicate that the low-cost and low-power MUN-APAD-OES provides a promising reliable method for on-site serum Li measurement and may also be extended to other elements.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Development of a Portable Method for Serum Lithium Measurement Based on Low-Cost Miniaturized Ultrasonic Nebulization Coupled with Atmospheric-Pressure Air-Sustained Discharge
- Date Crossref
- 24/09/2021
- Éditeur
- American Chemical Society (ACS)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
China University of Geosciences State Key Laboratory of Biogeology and Environmental Geology pays non établi dans la noticeUniversité ou école supérieure
-
Faculty of Material Science and Chemistry pays non établi dans la noticeUniversité ou école supérieure
State Key Laboratory of Biogeology and Environmental Geology — China University of Geosciences et Faculty of Material Science and Chemistry.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.