Real-World, Patient-Reported and Clinic Data from Individuals with Type 1 Diabetes Using the MiniMed 670G Hybrid Closed-Loop System

21Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: The purpose of this study was to collect 1 year of real-world data from individuals with type 1 diabetes (T1D) initiating the Medtronic 670G hybrid closed-loop insulin delivery system as part of usual care. We sought to expand current knowledge to understand how use of the system impacts patient-reported outcomes, in addition to clinical outcomes, for children and adults with T1D. Methods: Questionnaires were completed by the participant (and/or parent) before initiation of the 670G system (baseline) and at 6 weeks, 6 months, and 12 months from enrollment. Clinical data were obtained at routine clinical visits. Results: Of 132 participants who initiated Auto Mode, 80 completed the 12-month questionnaires while persisting with the system. Nearly all reported receiving adequate training on the 670G. Participant and parent-reported fear of hypoglycemia decreased by 6 and 11 points, respectively, from baseline to 12 months. More than half reported issues with sleep interruption at night due to alarms and 40% did not like frequent exits from Auto Mode. For the subset who had complete continuous glucose monitor data ( n = 27), mean percent time in target range (70–180 mg/dL) was 66% at baseline, and 74% and 68% at 6 and 12 months, respectively. Conclusions: With this study, we have captured real-time feedback from patients with T1D who initiated the 670G system and continued to use it over 12 months regarding their experience with the system. This has helped to illuminate both benefits and burdens associated with the first commercially available hybrid closed-loop system.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Real-World, Patient-Reported and Clinic Data from Individuals with Type 1 Diabetes Using the MiniMed 670G Hybrid Closed-Loop System
Date Crossref
25/11/2021
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Diabetes Management and ResearchPancreatic function and diabetesDiabetes and associated disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.