Aller au contenu principal
Accès ouvert déclaré 2021 article

Aortic valve replacement in pediatric patients: 30 years single center experience

14Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : at. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: The choice of aortic valve replacement needs to be decided in an interdisciplinary approach and together with the patients and their families regarding the need for re-operation and risks accompanying anticoagulation. We report long-term outcomes after different AVR options. METHODS: A chart review of patients aged < 18 years at time of surgery, who had undergone AVR from May 1985 until April 2020 was conducted. Contraindications for Ross procedure, which is performed since 1991 at the center were reviewed in the observed non-Ross AVR cohort. The study endpoints were compared between the mechanical AVR and the biological AVR cohort. RESULTS: From May 1985 to April 2020 fifty-five patients received sixty AVRs: 33 mechanical AVRs and 27 biological AVRs. In over half of the fifty-three AVRs performed after 1991 (58.5%; 31/53) a contraindication for Ross procedure was present. Early mortality was 5% (3/60). All early deaths occurred in patients aged < 1 year at time of surgery. Two late deaths occurred and survival was 94.5% ± 3.1% at 10 years and 86.4% ± 6.2% at 30 years. Freedom from aortic valve re-operation was higher (p < 0.001) in the mechanical AVR than in the biological AVR cohort with 95.2% ± 4.6% and 33.6% ± 13.4% freedom from re-operation at 10 years respectively. CONCLUSIONS: Re-operation was less frequent in the mechanical AVR cohort than in the biological AVR cohort. For mechanical AVR, the risk for thromboembolic and bleeding events was considerable with a composite linearized event rate per valve-year of 3.2%.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Aortic valve replacement in pediatric patients: 30 years single center experience
Date Crossref
08/09/2021
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Aortic Disease and Treatment ApproachesCongenital Heart Disease StudiesCardiac Valve Diseases and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.