Aller au contenu principal
Accès ouvert déclaré 2021 article

Clinical evaluation of Sofia Rapid Antigen Assay for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) among emergency department to hospital admissions

29Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Objective: To determine the utility of the Sofia SARS rapid antigen fluorescent immunoassay (FIA) to guide hospital-bed placement of patients being admitted through the emergency department (ED). Design: Cross-sectional analysis of a clinical quality improvement study. Setting: This study was conducted in 2 community hospitals in Maryland from September 21, 2020, to December 3, 2020. In total, 2,887 patients simultaneously received the Sofia SARS rapid antigen FIA and SARS-CoV-2 RT-PCR assays on admission through the ED. Methods: Rapid antigen results and symptom assessment guided initial patient placement while confirmatory RT-PCR was pending. The sensitivity, specificity, positive predictive values, and negative predictive values of the rapid antigen assay were calculated relative to RT-PCR, overall and separately for symptomatic and asymptomatic patients. Assay sensitivity was compared to RT-PCR cycle threshold (Ct) values. Assay turnaround times were compared. Clinical characteristics of RT-PCR–positive patients and potential exposures from false-negative antigen assays were evaluated. Results: For all patients, overall agreement was 97.9%; sensitivity was 76.6% (95% confidence interval [CI], 71%–82%), and specificity was 99.7% (95% CI, 99%–100%). We detected no differences in performance between asymptomatic and symptomatic individuals. As RT-PCR Ct increased, the sensitivity of the antigen assay decreased. The mean turnaround time for the antigen assay was 1.2 hours (95% CI, 1.0–1.3) and for RT-PCR it was 20.1 hours (95% CI, 18.9–40.3) (P < .001). No transmission from antigen-negative/RT-PCR–positive patients was identified. Conclusions: Although not a replacement for RT-PCR for detection of all SARS-CoV-2 infections, the Sofia SARS antigen FIA has clinical utility for potential initial timely patient placement.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical evaluation of Sofia Rapid Antigen Assay for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) among emergency department to hospital admissions
Date Crossref
24/06/2021
Éditeur
Cambridge University Press (CUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

SARS-CoV-2 detection and testingSARS-CoV-2 and COVID-19 ResearchCOVID-19 Clinical Research Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.