Aller au contenu principal
Accès ouvert déclaré 2021 article

Myocardial Flow Reserve Measurement During CZT-SPECT Perfusion Imaging for Coronary Artery Disease Screening: Correlation With Clinical Findings and Invasive Coronary Angiography—The CFR-OR Study

17Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Purpose: The aim of this study was to assess the results of cadmium zinc telluride (CZT)- single-photon emission computed tomography (SPECT) myocardial flow reserve (MFR) in coronary artery disease (CAD) screening regarding clinical risk and its correlation to invasive coronary angiography (ICA). Methods: A total of 137 patients (61 male and 76 female) referred for CAD screening myocardial perfusion imaging (MPI) between November 2018 and April 2020 were included in the CFR-OR prospective trial. The 10-year risk of cardiovascular death according to the European Society of Cardiology (SCORE) was calculated. SPECT 1-day 99mTc-tetrofosmin protocol was acquired on CZT cardiac-dedicated pinhole cameras. Low-dose thoracic CT was used for coronary calcium score (CCS) evaluation. ICA, when performed within 3 months, was also analyzed. Results: Mean SCORE and mean global MFR were, respectively, 4 ± 3.1% and 2.50 ± 0.74; 34 patients had impaired CFR (using a threshold of 2). There was a significant inverse correlation between MFR and SCORE (p = 0.006), gender (p = 0.019), and number of cardiovascular risk factors (p = 0.01). MFR was significantly reduced in patients with CCS above 1 (p = 0.01). No significant correlation was found between MFR and individual cardiovascular risk factors (dyslipidemia, hypertension, diabetes, or family history of CAD). A total of 23 patients underwent ICA. Global MFR SPECT sensitivity and specificity were 83.3 and 100 %, respectively, with an area under the curve of 0.94. Conclusion: Adding MFR to SPECT MPI for CAD screening on CZT camera may contribute to high-risk patient identification and enhance diagnostic performances. MFR could help physician decision to perform ICA.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Myocardial Flow Reserve Measurement During CZT-SPECT Perfusion Imaging for Coronary Artery Disease Screening: Correlation With Clinical Findings and Invasive Coronary Angiography—The CFR-OR Study
Date Crossref
04/06/2021
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Imaging and DiagnosticsCoronary Interventions and DiagnosticsAcute Myocardial Infarction Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.