Aller au contenu principal
Accès ouvert déclaré 2021 article

Invasive and Non-invasive Dynamic Parameters to Predict Fluid Responsiveness After Off-pump Coronary Surgery

2Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : ru. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: This study aimed to assess the predictive value of invasive and non-invasive dynamic parameters for evaluation of fluid responsiveness after off-pump coronary artery bypass grafting. METHODS: Thirty-two adult patients after off-pump coronary surgery were enrolled into a single-center pilot prospective observational study. After arrival to the intensive care unit, all patients received standard fluid challenge test to assess fluid responsiveness. The patients with an increase in cardiac index ≥ 15% after the test were defined as fluid responders. We measured pulse pressure variation using 2 monitoring systems (PPVPiCCO and PPVNK), stroke volume variation, heart-lung interaction index, and plethysmogram variability index before and after standard fluid challenge test. RESULTS: After intensive care unit admission, the absolute values of stroke volume variation, PPVPiCCO, PPVNK, and heart-lung interaction index were significantly higher among fluid responders (P < .05). Response to standard fluid challenge test was predicted by dynamic assessment of PPVPiCCO (area under the curve 0.84), PPVNK (area under the curve 0.71), stroke volume variation (area under the curve 0.77), and heart-lung interaction index (area under the curve 0.77) (P < .05). The plethysmogram variability index value did not demonstrate any predictive ability regarding fluid responsiveness (area under the curve 0.5, P =.1). CONCLUSIONS: In patients after off-pump coronary surgery, both invasive parameters such as pulse pressure and stroke volume variations and non-invasive parameter such as heart-lung interaction index are able to predict fluid responsiveness. Thus, these dynamic parameters can be used to guide fluid therapy during the early postoperative period after off-pump coronary surgery.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Invasive and Non-invasive Dynamic Parameters to Predict Fluid Responsiveness After Off-pump Coronary Surgery
Date Crossref
07/03/2022
Éditeur
Galenos Yayinevi
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hemodynamic Monitoring and TherapySepsis Diagnosis and TreatmentTrauma, Hemostasis, Coagulopathy, Resuscitation

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.