Performance evaluation of a solar pump for a landscape irrigation system
Rattachement africain : Égypte. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Experiments were performed at a private garden in Al-Qaddbah, Al-Gharbia Governorate, Egypt. The latitude and longitude of the experiment site are 30°56'37''N and 30°47'01'' E, respectively, and the altitude equals 30 m, at the 2019 season, the total landscape area (13.5m x 9m) was divided into 6 treatments each of an area (20.25 m2), three plots were operated using solar system while the other three plots were operated using electric system. The irrigation systems were similar, 4 multi-stream sprayers, (90◦) and the distance between the sprayers was (4.5*4.5 m), different operating times were applied on each plot, under local climatic and working conditions. All the plots were planted with turfgrass (Passpalm10). The obtained results show, at solar energy powered system, uniformity coefficient increased from (65% - 75%) at operating time (10 –30 min), then it decreased during operating time (40 - 60 min), while at electric energy powered system the averages of the uniformity coefficient were (76% - 80%), at operating time (10 –40 min), while at operating time (45 - 60 min) the uniformity coefficient decreased to (75%), due to the silt clogging in the sprayers' filters. The energy saving reached (63%) with solar energy operation rather than electric energy operation in the summer season. The least total cost was (351 L.E/m2/year) at the landscape area (A3 60.75m2), which was irrigated on 3 cycles per day to give the highest uniformity coefficient (75%). When operating the solar batteries at full charge 3 - 4 times for a plot area of (20.25 m2). The hydraulic power obtained was (17.86 –26.74 W), the sprayer radius was (5.3 –5.8 m), at an average pressure of (1.9 -2.5 bar) which gave the best uniformity coefficient. The turf quality index was higher using electric motor rather than solar motor.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Performance evaluation of a solar pump for a landscape irrigation system
- Date Crossref
- 24/05/2021
- Éditeur
- Egypts Presidential Specialized Council for Education and Scientific Research
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Ain Shams University Égypte (code pays fourni par la source)Université ou école supérieure
-
Faculty of Agriculture Agricultural Engineering Department Cairo, Égypte (pays nommé en fin d’affiliation)Université ou école supérieure
Ain Shams University (Égypte) et Agricultural Engineering Department — Faculty of Agriculture (Cairo, Égypte). Pays d’affiliation : Égypte.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.