Experimental use of stereotactic radiosurgery in non-invasive interventions in arrhythmology
Rattachement africain : ru. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Funding Acknowledgements Type of funding sources: None. Background Non-invasive stereotactic treatment with particle beam may be considered as a promising alternative to catheter ablation in patients with different types of tachyarrhythmias. Purpose the purpose of the experimental study was to develop a technique for stereotactic radioablation in order to create a stable functional and morphological damage in heart tissue with subsequent analysis of precision, efficiency and safety of the exposure in the long-term observation period. Materials and methods The research was carried out on four domestic pigs. The animals were 10-12 weeks old, the average weight was 30 ± 2.7 kg. Beam delivering linear accelerator was used during the experiment. Animals were divided into groups according to the zones of planned radiation exposure: 1st animal – atrioventricular (AV) node (dose 35 Gy), 2nd animal - AV node and the apex of the left ventricle (LV) (dose 40/35 Gy, respectively), 3rd animal - pulmonary veins muscle sleeves and left atrium (dose 30 Gy), 4th - AV node and free wall of the LV (dose 45/40 Gy, respectively). Under intravenous sedation with hemodynamic monitoring, contrast-based CT scan of the heart was performed to assess the degree of displacement of the heart chambers in one respiratory and cardiac cycle- and to assess the anatomy of the chambers of the heart and adjacent organs. The allocation and the contouring of the target zones were carried out in three projections: axial, frontal and sagittal. For electrophysiological control, loop recorders were implanted in each animal. The average exposure time was 11 ± 7 minutes. The long-term follow-up period was six months, followed by morphological examination of autopsy material. The study followed the "Principles of laboratory animal care". Results The average follow-up period after the experiment was 134.75 ± 77.34 days. The electrophysiological effect of the ablation was considered to be achieved in cases of complete AV-block development. This effect was developed in two out of three animals, whose AV-node was exposed: 2nd animal - 40 Gy on 108th day of observation and 4th animal - 45 Gy on 21st day of observation. No cardiac arrhythmias were recorded in all cases. The results of macro- and microscopic examination showed significant changes in the target zones. These areas had precise but uneven damage boundaries, which were within the planned ones (conformal exposure with a high degree of precision). The transmural nature of the changes was noted as well (pic. 1 A, B, C). Massive fields of fibrous tissue of various degrees of maturity (with a predominance of subepicardial localization) with focal hemorrhages of various ages and granulations were detected, which were surrounded by cardiomyocytes with coagulated and vacuolated cytoplasm (pic. 1 D, E, F). Conclusion The use of non-invasive stereotactic treatment of tachyarrhythmias has high potential in modern arrhythmology as an alternative ablation method. Abstract Figure. Macro- and microscopic results
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Experimental use of stereotactic radiosurgery in non-invasive interventions in arrhythmology
- Date Crossref
- 01/05/2021
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.