Aller au contenu principal
2021 article

Precision modeling of the IBA Universal Nozzle double scattering mode at the University Proton Therapy Dresden for Monte Carlo simulation

5Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, be. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Monte Carlo (MC) simulations are indispensable for many research and advanced clinical questions in proton therapy (PT). However, the necessary site-specific modeling of a double scattering (DS) PT system is extensive and challenging and requires a clear strategy. This work describes a comprehensive method for precise and accurate modeling of a DS nozzle that minimizes additional measurement effort. A detailed model of the IBA universal nozzle is created within the TOPAS simulation framework. This model is subsequently fine-tuned using a step by step procedure to match the same dose profiles used for the commissioning of the treatment planning system. In the proposed bottom-up approach, the geometry of beam-shaping elements is first adjusted to measured quantities and then the beam and model properties are optimized using iterative methods. The resulting dose distributions are validated with a set of independent measurement data to estimate the achieved quality. The resulting simulated dose distributions agree well with the data and show residual range differences of maximum 0.6 mm. The shape of the SOBP plateau regions is accurately reproduced with a spread of the residuals below 1% (i.e., near to the statistical limit) over a large part of the machine settings. The simulated lateral dose profiles, although not directly included in the optimization, match the shape of the validation data better than 0.14 mm. The minimal measurement effort and high-precision proton field modeling make this method attractive, in particular, for retrospective beam modeling needed in clinical outcome or relative biological effectiveness studies after DS treatment.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Precision modeling of the IBA Universal Nozzle double scattering mode at the University Proton Therapy Dresden for Monte Carlo simulation
Date Crossref
01/03/2021
Éditeur
IOP Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiation Therapy and DosimetryX-ray Spectroscopy and Fluorescence AnalysisRadiation Effects in Electronics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.