OBJECTIVE: Monitoring of viral loads (VL) for hepatitis B and C viruses (HBV; HCV) is essential to evaluate disease progression and treatment response. Automated, random-access rapid systems are becoming standard to provide clinicians with reliable VL. The aim of this study was to evaluate the analytical performances of the recently launched NeuMoDx™ for HBV-DNA and HCV-RNA quantification. METHODS: Clinical samples routinely quantified on the Beckman-Veris system were either retrospectively (frozen samples; HBV n = 178, HCV n = 249), or in parallel (fresh primary tubes; HBV n = 103, HCV n = 117) tested using NeuMoDx™. Linearity range was assessed on serial dilutions of high-titre plasmas containing different genotypes for HBV (A-E, n = 9) and HCV (1a,1b,2-5, n = 12). RESULTS: Overall test failure, mostly internal control amplification failure, was 2.3% and was not influenced by matrix types (fresh or frozen). For HBV VL, κ agreement was 74%, with 27 (12.6%) discrepancies. Correlation between HBV assays on 72 quantified samples by both methods was excellent (r = 0.963) with a mean bias (NeuMoDx™-Veris) of 0.21 log IU/mL. For HCV VL, κ agreement reached 94%, with 9 (2.8%) discrepancies. The r correlation factor between assays on 104 samples was 0.960 with a mean bias of -0.14 log IU/mL (NeuMoDx™-Veris). Serial dilutions confirmed the claimed linear ranges for all analysed HBV and HCV genotypes. The mean turnaround time was 72 minutes (range 55-101 minutes) for HBV and 96 minutes (range 78-133 minutes) for HCV. CONCLUSION: Results obtained on the NeuMoDx™ confirmed the overall good functionality of the system with a short turn-around-time, full traceability and easy handling. These results on HBV and HCV VL look promising and should be challenged with further comparisons.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Performances of NeuMoDx™, a random-access system for hepatitis B virus DNA and hepatitis C virus RNA quantification
Date Crossref
01/11/2021
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Hepatitis B Virus StudiesHepatitis C virus researchMolecular Biology Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.