Aller au contenu principal
Accès ouvert déclaré 2021 article

Multinational evaluation of the BioFire® FilmArray® Pneumonia plus Panel as compared to standard of care testing

63Citations signalées — pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

This study compared standard of care testing (SOC) to BioFire® FilmArray® Pneumonia plus Panel (PNplus). PNplus detects 15 bacteria with semiquantitative log bin values, 7 antibiotic resistance markers, three atypical bacteria (AB), and eight viral classes directly from bronchoalveolar lavage-like specimens (BLS) and sputum-like specimens (SLS). Fifty-two laboratories from 13 European countries and Israel tested 1234 BLS and 1242 SLS with PNplus and SOC. Detection rates and number of pathogens/samples were compared for PNplus pathogens. PNplus bin values and SOC quantities were compared. Three thousand two hundred sixty-two bacteria in PNplus were detected by PNplus and/or SOC. SOC detected 57.1% compared to 95.8% for PNplus (p ≤ 0.0001). PNplus semiquantitative bin values were less than SOC, equal to SOC, or greater than SOC in 5.1%, 25.4%, and 69.6% of results, respectively. PNplus bin values were on average ≥ 1 log than SOC values (58.5% 1-2 logs; 11.0% 3-4 logs). PNplus identified 98.2% of MRSA and SOC 55.6%. SOC detected 73/103 AB (70.9%) and 134/631 viruses (21.2%). PNplus detected 93/103 AB (90.3%) and 618/631 viruses (97.9%) (p ≤ 0.0001). PNplus and SOC mean number of pathogens/samples were 1.99 and 1.44, respectively. All gram-negative resistance markers were detected. PNplus and SOC results were fully or partially concordant for 49.1% and 26.4% of specimens, respectively. PNplus was highly sensitive and detected more potential pneumonia pathogens than SOC. Semiquantification may assist in understanding pathogen significance. As PNplus generates results in approximately 1 h, PNplus has potential to direct antimicrobial therapy in near real time and improve antimicrobial stewardship and patient outcomes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Multinational evaluation of the BioFire® FilmArray® Pneumonia plus Panel as compared to standard of care testing
Date Crossref
02/03/2021
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Pneumonia and Respiratory InfectionsNosocomial Infections in ICUBacterial Identification and Susceptibility Testing

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.