Le résumé fourni par la source

OBJECTIVES: To determine the occurrence of vascular complications (VCs) following transfemoral transcatheter aortic valve replacement (TAVR) with new-generation devices according to the use of a crossover technique (COT). BACKGROUND: The use of a COT (with/without balloon) has been associated with a reduction of VCs in TAVR patients. However, scarce data support its use with second-generation devices. Also, its potential benefit in obese patients (at high-risk of VCs) has not been elucidated. METHODS: A multicenter study including 2214 patients who underwent full percutaneous transfemoral TAVR (COT, 1522 patients; no COT, 692 patients). Thirty-day events were evaluated according to the use of a COT using a multivariate logistic regression model. A subanalysis was performed in obese patients. RESULTS: Primary access major VCs (3.5% COT vs 3.9% no COT; P=.19), major/life-threatening bleeding (3.4% COT vs 2.0% no COT; P=.33), and mortality rates (2.4% COT vs 2.6% no COT; P=.23) were similar between groups. However, minor VCs (11.7% COT vs 5.9% no COT; P<.001) and postprocedural acute renal failure (8.9% COT vs 3.9% no COT; P<.001) were higher in patients undergoing the COT. In the overall cohort, percutaneous closure device failure was more frequent in obese patients (4.0% in the obese group vs 1.9% in the non-obese group; P<.01), but these differences were no longer significant in those undergoing a COT (3.4% in the obese group vs 2.0% in the non-obese group; P=.12). Indeed, in the subset of obese patients, the COT tended to be associated with fewer VCs (3.4% COT vs 5.9% no COT; P=.09). CONCLUSIONS: The use of a COT was not associated with a reduction of major VCs or improved outcomes. However, some patient subsets, such as those with higher body mass index, may benefit from the use of a COT. These findings would suggest the application of a tailored strategy, following a risk-benefit assessment in each TAVR candidate.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Clinical Impact of Crossover Techniques for Primary Access Hemostasis in Transfemoral Transcatheter Aortic Valve Replacement Procedures
Date Crossref
18/02/2021
Éditeur
HMP Communications, LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesAntiplatelet Therapy and Cardiovascular Diseases

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.