Diagnostic performance of pulmonary ultrasonography and a clinical score for the evaluation of fluid overload in haemodialysis patients

4Citations signalées, ce qui n’est pas une note de qualité
8Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: There is no feasible benchmark in daily routine to estimate the hydration status of haemodialysis patients, which is essential to their management. OBJECTIVE: We performed a study in haemodialysis patients to assess the diagnostic performance of pulmonary ultrasound and clinical examination for the evaluation of fluid overload using transthoracic echocardiography as a gold standard. METHODS: Thirty-one patients receiving chronic haemodialysis patients were included. Evaluation of hydration status was assessed weekly before haemodialysis sessions using clinical and Echo Comet Score from pulmonary ultrasound and transthoracic echocardiography (reference method). RESULTS: Five patients had a transthoracic echocardiography overload. Compared with transthoracic echocardiography, the diagnostic performance of the clinical overload score has a sensitivity of 100%, a specificity of 77%, a positive predictive value of 50% and a negative predictive value of 100% with a κ of 0.79. Only orthopnoea (P=0.008), jugular turgor (P=0.005) and hepatic-jugular reflux (P=0.008) were significantly associated with transthoracic echocardiography overload diagnosis. The diagnostic performance of Echo Comet Score by pulmonary ultrasound has a sensitivity of 80%, a specificity of 58%, a positive predictive value of 26% and a negative predictive value of 94%. Ten patients (32.3%) had an increase of extravascular pulmonary water without evidence of transthoracic echocardiography or clinical overload. CONCLUSIONS: Our clinical score has a convincing diagnostic performance compared to transthoracic echocardiography and could be easily used in daily clinical routine to adjust dry weight. The evaluation of the overload using pulmonary ultrasound seems poorly correlated with the overload evaluated by transthoracic echocardiography. Extravascular pulmonary water undetected by clinical examination and transthoracic echocardiography remains a parameter that requires further investigation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Diagnostic performance of pulmonary ultrasonography and a clinical score for the evaluation of fluid overload in haemodialysis patients
Date Crossref
01/02/2021
Éditeur
JLE
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hemodynamic Monitoring and TherapyDialysis and Renal Disease ManagementUltrasound in Clinical Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.