Novel Experience in Hybrid Tracers
Rattachement africain : ch, it, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: The clinical introduction of a radioactive and fluorescent hybrid tracer allowed for preoperative lymphatic mapping and intraoperative real-time fluorescence tracing of the sentinel lymph node (SLN) by a single injection. The aim of this feasibility study is to evaluate the first-in-human use of the hybrid tracer by combining indocyanine green (ICG) and radiocolloid based on Nanotop compound (99mTc Nanotop) for SLN biopsy (SLNB) in breast cancer patients. METHODS: The day before surgery, ICG-99mTc Nanotop was injected periareolarly in breast cancer patients scheduled for SLNB. Planar lymphoscintigraphic (PL) and SPECT/CT images were then acquired. An intraoperative optonuclear probe was used to detect SLN gamma and fluorescent signals. The harvested SLNs were examined by hematoxylin-eosin staining, and patients were clinically evaluated 1 month after surgery. RESULTS: Twenty-one consecutive patients were enrolled. The PL and SPECT/CT techniques identified at least 1 SLN in all patients for a preoperative sentinel detection rate of 100%. SPECT/CT revealed 3 additional lymph nodes in the same nodal basin, which had not been visualized on conventional PL (κ = 0.747; P < 0.005). All 30 preoperative SLNs were localized and excised up to 16 hours after injection. The counts measured via gamma tracing showed a very strong correlation with those measured via near-infrared fluorescent tracing (P < 0.005, r = 0.964). No adverse reactions were observed. CONCLUSIONS: The SLNB technique used with the ICG-99mTc Nanotop tracer resulted to be feasible, reliable, and safe. This hybrid compound allowed us to obtain excellent performance in terms of both preoperative lymphatic mapping and intraoperative SLN detection in breast cancer patients.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Novel Experience in Hybrid Tracers
- Date Crossref
- 15/12/2020
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.