Baseline NT‐proBNP Accurately Predicts Symptom Response to Transcatheter Aortic Valve Implantation
Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background Up to 30% of patients undergoing transcatheter aortic valve implantation (TAVI) experience minimal symptomatic benefit or die within 1 year, indicating an urgent need for enhanced patient selection. Previous analyses of baseline NT‐proBNP (N‐terminal pro‐brain natriuretic peptide) and TAVI outcomes have assumed a linear relationship, yielding conflicting results. We reexamined the relationship between baseline NT‐proBNP and symptomatic improvement after TAVI. Methods and Results Symptom status, clinical and echocardiographic data, and baseline NT‐proBNP were reviewed from 144 consecutive patients undergoing TAVI for severe symptomatic aortic stenosis. The primary end point was change in New York Heart Association functional class at 1 year. There was a nonlinear, inverted‐U relationship between log‐baseline NT‐proBNP and post‐TAVI change in NYHA class ( R 2 =0.4559). NT‐proBNP thresholds of <800 and >10 000 ng/L accurately predicted no symptomatic improvement at 1 year (sensitivity 88%, specificity 83%, positive predictive value 72%, negative predictive value 93%). In adjusted analyses, baseline NT‐proBNP outside this “sweet‐spot” range was the only factor independently associated with poor functional outcome (high: NT‐proBNP >10 000 ng/L, odds ratio [OR], 65; 95% CI, 6–664; low: NT‐proBNP <800 ng/L, OR, 73; 95% CI, 7–738). Conclusions Baseline NT‐proBNP is a useful prognostic marker to predict poor symptom relief after TAVI and may indicate when intervention is likely to be futile. Both low (<800 ng/L) and very high (>10 000 ng/L) levels are strongly associated with poor functional outcome, suggesting an alternative cause for symptoms in the former scenario and an irrevocably diseased left ventricle in the latter. Further evaluation of this relationship is warranted.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Baseline NT‐proBNP Accurately Predicts Symptom Response to Transcatheter Aortic Valve Implantation
- Date Crossref
- 01/12/2020
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.