Aller au contenu principal
Accès ouvert déclaré 2020 preprint

Safety and tolerability of prescribed usage of Derise® (Darbepoetin Alfa, Hetero) in symptomatic anemia: A Post Marketing Surveillance Study

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : in. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background This post marketing surveillance, observational, prospective, safety study evaluated the safety, tolerability and long term immunogenicity of prescribed usage of Darbepoetin alfa, (DA-α, manufactured by Hetero Biopharma) in Indian patients with chronic kidney disease with anemia.Methods All patients with anemia of chronic kidney disease prescribed Hetero-Darbepoetin were the target patient population. The present study gathered the data from 503 Hetero-Darbepoetin alfa prescribed patients. This study collected information of patient demography, patient's medical history, concomitant medications, action taken with respect to Hetero-Darbepoetin-alfa, AE details (AE term, start date, stop date, severity, action taken, outcome and causality), periodic Hemoglobin (Hb) levels and abnormal laboratory tests results until treatment is discontinued or the patient is lost to follow-up. Immunogenicity data was collected in 121 patients at the end of treatment and after 1 year. Statistical analyses were performed to explore and analyze details of individual case safety reports of adverse events such as incidence, severity, seriousness, outcome, duration, action taken, and causality relationship of individual adverse event (AE) to the prescribed study drug. Results 87 AEs were reported in this study and most of them were mild to moderate in intensity. No deaths or serious adverse events (SAEs) were reported in this study. Anti-drug antibodies were not detected in any subject at the end of treatment phase and after 12 months long term follow up period. Baseline mean Hemoglobin value was 8.34 (SD 1.24) g/dL and last visit mean Hemoglobin value was 10.42 (SD 1.28) g/dL. The mean difference between baseline and last visit was 2.10 [2.00, 2.20], statistically significant (p-value <.0001). Conclusions The safety and tolerability of the usage of DA-α (manufactured by Hetero Biopharma) is similar to that reported in the published literature of the innovator. No patients showed anti-drug antibodies after treatment. Additionally, the patients also showed significant improvement in hemoglobin levels, compared to baseline.Clinical Trial Registry Number: CTRI/2017/04/008338 [Registered on CTRI http://ctri.nic.in/Clinicaltrials/login.php : 12/04/2017]; Trial Registered Retrospectively

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Safety and tolerability of prescribed usage of Derise® (Darbepoetin Alfa, Hetero) in symptomatic anemia: A Post Marketing Surveillance Study
Date Crossref
24/11/2020
Éditeur
Springer Science and Business Media LLC
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Erythropoietin and Anemia TreatmentIron Metabolism and DisordersDialysis and Renal Disease Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.