Perceived luminance contrast of stereoscopic patterns
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Previous studies have shown that luminance contrast under monocular viewing appears comparable to that under binocular viewing above threshold. However, little attention has been paid to perceived luminance contrast under stereoscopic viewing. Here we compared perceived luminance contrast of patterns with binocular disparity to that of zero-disparity patterns. Two vertical Gabor patterns were successively presented in each trial. The first pattern was the standard stimulus that had no binocular disparity. The second pattern was the comparison stimulus that had -1, -0.5, -0.25, 0, 0.25, 0.5, or 1° of binocular disparity. Five observers judged which pattern had the higher luminance contrast. Luminance contrast of the standard stimulus was set to -26 or -8 dB re 1 (5 % or 40 % of Michelson contrast). Luminance contrast of the comparison stimulus was varied according to a one-up one-down staircase method with a step size of 1.5 dB. Each staircase terminated after 6 reversals. The PSEs were determined by averaging the last 4 reversals of two interleaved staircases (8 reversals in total). The results showed that the mean PSEs for -8 dB standard contrast significantly decreased as the absolute value of binocular disparity increased. The mean PSEs were -9.4 and -11.0 dB at -1 and 1° of binocular disparity, respectively, whereas it was -8.5 dB at zero disparity. That is, luminance contrast of the patterns with binocular disparity was perceived approximately 1.10 and 1.34 times higher than that of a zero-disparity pattern. There was a similar significant trend for -26 dB standard contrast, although the effect was relatively small. The results will be discussed in terms of interocular suppression and stereoscopic vision.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Perceived luminance contrast of stereoscopic patterns
- Date Crossref
- 20/10/2020
- Éditeur
- Association for Research in Vision and Ophthalmology (ARVO)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Kanagawa University pays non établi dans la noticeUniversité ou école supérieure
-
The University of Tokyo pays non établi dans la noticeUniversité ou école supérieure
Kanagawa University et The University of Tokyo.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.