Evaluation of Changes in Intraocular Pressure with a Noncontact Tonometer in Healthy Volunteers
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Purpose: We investigated whether or not intrasession or intersession fluctuations in intraocular pressure occur in healthy people using a noncontact tonometer. Materials and Methods: A noncontact tonometer was used to measure intraocular pressure in the bilateral eyes of healthy subjects for 5 consecutive days. Paired t -tests and one- and two-way repeated-measures analyses of variance were performed for the acquired data. A p -value < 0.05 was considered to indicate statistical significance. Results: Eighty eyes of 40 healthy subjects were enrolled in the study. On day 1, intraocular pressure was significantly higher in the right eye than in the left eye ( P = 0.014). The one-way repeated-measures analysis of variance revealed that intraocular pressure in the left eye was significantly lower on day 1 than on days 2 to 5 ( P = 0.000– 0.018); however, there were no significant differences among intraocular pressures measured on days 1 to 5 in the right eye. The two-way repeated-measures analysis of variance revealed no significant difference in intraocular pressure between the right and left eyes ( P = 0.913). Conclusion: Although measurements using the noncontact tonometer were relatively stable, intraocular pressure was high on day 1. Keywords: intraocular pressure, noncontact tonometer, normal subject, repeated measurement, intrasession variability
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- <p>Evaluation of Changes in Intraocular Pressure with a Noncontact Tonometer in Healthy Volunteers</p>
- Date Crossref
- 01/10/2020
- Éditeur
- Informa UK Limited
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Niigata University of Health and Welfare pays non établi dans la noticeUniversité ou école supérieure
-
Kameda Medical Center pays non établi dans la noticeÉtablissement de santé
-
Niigata University Division of Ophthalmology and Visual Sciences pays non établi dans la noticeUniversité ou école supérieure
-
Kitasato University pays non établi dans la noticeUniversité ou école supérieure
-
Kawasaki Medical School pays non établi dans la noticeUniversité ou école supérieure
-
Kawasaki University of Medical Welfare pays non établi dans la noticeUniversité ou école supérieure
-
Faculty of Medical Technology Department of Orthoptics and Visual Sciences pays non établi dans la noticeUniversité ou école supérieure
-
Graduate School of Health and Welfare Major in Medical and Rehabilitation Sciences pays non établi dans la noticeUniversité ou école supérieure
-
Yaoeda Eye Clinic Department of Ophthalmology pays non établi dans la noticeÉtablissement de santé
-
Faculty of Sensory and Motor Control Department of Vision Science pays non établi dans la noticeUniversité ou école supérieure
-
Department of Ophthalmology pays non établi dans la noticeInstitution
-
Faculty of Rehabilitation Department of Orthoptics pays non établi dans la noticeUniversité ou école supérieure
Niigata University of Health and Welfare, Kameda Medical Center et Division of Ophthalmology and Visual Sciences — Niigata University, avec 9 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.