Aller au contenu principal
Accès ouvert déclaré 2020 article

Searching high and low for the gist in 3D medical images

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Radiologists can identify the gist of a medical image (abnormal vs. normal) better than chance in static 2D images, after presentations of half a second or less (Evans et al., 2013; 2016). The gist of 2D real-world scenes is carried by low spatial frequency channels, which convey the structural layout of scenes (Schyns & Oliva, 1994). In contrast the gist signal in 2D mammography is carried by high spatial frequency channels (Evans et al. 2016). Standard practice in radiology is moving to 3D modalities, where each case consists of a series of images that are assembled into a virtual stack. Radiologists can extract gist from movies of these stacks (Trevino et al., 2019; Wu & Wolfe, 2019). We do not know which channels carry the gist from 3D stacks. We tested 51 radiologists with prostate mpMRI experience on 56 cases, each comprising a stack of 26 T2-weighted prostate mpMRI images. Lesions (Gleason scores 6-9) were present in 50% of cases. A trial consisted of a movie of a single case presented at 48 ms/slice. After each case, participants localized the cancerous lesion on a prostate sector map, then indicated whether a cancerous lesion was presented, and gave a confidence rating. Radiologists were divided equally into three groups who viewed either unfiltered images, low-pass (< 2 cycles/°) filtered images, or high-pass (> 6 cycles/°) filtered images. Unfiltered detection and localization performance were higher than chance (d’ = 0.28; localization = 31%). Radiologists performed at chance when detecting lesions in high-pass filtered images (d’ = 0.16), and were significantly lower than chance for low-pass filtered images (d’ = -0.23). Our data indicate that gist perception from 3D prostate MRI relies on spatial frequency channels between 2 and 6 cycles/°. These findings emphasize that scene gist is highly dependent on task and context.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Searching high and low for the gist in 3D medical images
Date Crossref
20/10/2020
Éditeur
Association for Research in Vision and Ophthalmology (ARVO)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Imaging and AnalysisMedical Image Segmentation TechniquesAI in cancer detection

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.