CT artifacts after contrast media injection in chest imaging: evaluation of post-processing algorithms, virtual monoenergetic images and their combination for artifact reduction
Rattachement africain : us, ch, de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: After injection into a brachial vein, high contrast media concentration in axillary and subclavian veins can cause artifacts that impair diagnostic utility. This study assessed artifact reduction by artifact-reduction-algorithms (ARA) and virtual-monoenergetic-images (VMI), as well as their combination (VMIARA) compared to conventional CT-images (CI). Methods: Forty-six spectral-detector-CT (SDCT) examinations of patients that received ARA-reconstructions due to perivenous-artifacts were included in this retrospective study. CI, ARA, VMI, and VMIARA (range: 70–200 keV) were reconstructed. Objective analysis was performed with ROI-based assessment of mean and standard deviation of attenuation (HU) in hypo- and hyperdense artifacts and impaired muscle and arteries as well as artifact-free reference-tissue. Extent of artifact reduction, assessment of surrounding soft tissue and vessels, and appearance of new artifacts were rated visually by two radiologists. Results: Hypo- and hyperdense artifacts showed significant improvement as evidenced by decreasing attenuation differences between artifact impaired and artifact-free reference tissue in ARA, VMI ≥80 keV, and VMIARA between 70–200 keV (e.g., CI/ARA/VMI100keV/VMIARA100keV: hypodense artifacts, (−)264.8±150.9/(−)87.1±78.9/(−)48.6±64.6/9.9±63.9 HU; P<0.001); hyperdense artifacts, 164.2±51.1/82.1±73.2/7.9±34.7/(−)17.3±50.7 HU; P<0.001). Artifacts impairing surrounding muscle and arteries were also reduced by all three approaches. In visual assessment, ARA, VMI ≥100 keV, and VMIARA between 70–200 keV also showed significant artifact reduction and improved assessment; however, for assessment of arteries improvement was not significant using ARA alone. New artifacts were reported, particularly at higher keV-values. Conclusions: In presence of perivenous-artifacts, ARA, VMI and their combination allow for significant artifact reduction; however, their combination and VMI as a standalone approach yielded best results and should therefore be used, if available.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- CT artifacts after contrast media injection in chest imaging: evaluation of post-processing algorithms, virtual monoenergetic images and their combination for artifact reduction
- Date Crossref
- 01/01/2021
- Éditeur
- AME Publishing Company
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.