Adaptation Allowing for Bronchial Blocker Proximal Port Filtration during Lung Isolation for Patients with Airborne Precautions

3Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : us, ca, ru. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

AIRBORNE precautions are recommended in patients with bacterial and viral infections transferred via aerosolization (including Mycobacterium tuberculosis, rubeola, varicella, influenza and coronavirus disease 2019 [COVID-19]). Surgical procedures requiring lung isolation during airborne precautions require adaptations to limit environmental contamination.1A double lumen tube or bronchial blocker may be used for lung isolation.2 An unfiltered, open airway is problematic during airborne precautions. Previously described, an antiviral filter should be placed on the surgical lung lumen of a double lumen tube (fig. 1).1,3After positioning, opening of the bronchial blocker proximal port to the atmosphere allows for surgical lung deflation. The Arndt Endobronchial Blocker Set (Cook Medical, USA) contains a continuous positive airway pressure 15-mm adaptor, which when inserted into the proximal port facilitates antiviral filter application (fig. 2A). The Fuji Uniblocker (Ambu Inc., USA) lacks a continuous positive airway pressure adaptor. The 15-mm connector from a 3.0 endotracheal tube fits within the proximal end of a 9.0 Fr Fuji Uniblocker (fig. 2B). Also, the Rapi-Fit Adaptor (Cook Medical) within the 19 Fr Aintree Intubation Catheter Set (Cook Medical) attaches around the proximal end of a bronchial blocker, providing a 15-mm connection (fig. 2C).Using these adaptive measures in six airborne precaution patients, lung isolation has been successful. Clinically, the low-resistance antiviral filter did not impede lung deflation using a double lumen tube or bronchial blocker. Although bronchial blocker proximal port aspiration may facilitate deflation, this may unnecessarily increase aerosolization risk. Supporting the antiviral filter prevents dislodgment of the double lumen tube or bronchial blocker. Using the techniques described, lung isolation in patients requiring airborne precautions has been successful.The authors declare no competing interests.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Adaptation Allowing for Bronchial Blocker Proximal Port Filtration during Lung Isolation for Patients with Airborne Precautions
Date Crossref
08/09/2020
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Airway Management and Intubation TechniquesCardiac Arrest and ResuscitationRespiratory Support and Mechanisms

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.