Aller au contenu principal
2020 article

Indirect visual guided fracture reduction robot based on external markers

12Citations signalées — pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Traditional fracture reduction surgery cannot ensure the accuracy of the reduction while consuming the physical strength of the surgeon. Although monitoring the fracture reduction process through radiography can improve the accuracy of the reduction, it will bring radiation harm to both patients and surgeons. METHODS: We proposed a novel fracture reduction solution that parallel robot is used for fracture reduction surgery. The binocular camera indirectly obtains the position and posture of the fragment wrapped by the tissue by measuring the posture of the external markers. According to the clinical experience of fracture reduction, a path is designed for fracture reduction. Then using position-based visual serving control the robot to fracture reduction surgery. The study is approved by the ethics committee of the Rehabilitation Hospital, National Research Center for Rehabilitation Technical Aids, Beijing, China. RESULTS: Ten virtual cases of fracture were used for fracture reduction experiments. The simulation and model bone experiments are designed respectively. In model bone experiments, the fragments are reduced without collision. The angulation error after the reduction of this method is 3.3° ± 1.8°, and the axial rotation error is 0.8° ± 0.3°, the transverse stagger error and the axial direction error after reduction is 2 ± 0.5 mm and 2.5 ± 1 mm. After the reduction surgery, the external fixator is used to assist the fixing, and the deformity will be completely corrected. CONCLUSIONS: The solution can perform fracture reduction surgery with certain accuracy and effectively reduce the number of radiographic uses during surgery, and the collision between fragments is avoided during surgery.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Indirect visual guided fracture reduction robot based on external markers
Date Crossref
12/09/2020
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Facial Trauma and Fracture ManagementSoft Robotics and ApplicationsSpinal Fractures and Fixation Techniques

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.