Aller au contenu principal
Accès ouvert déclaré 2020 article

The First Implantation of the Novel Biological Heart Valve, the Inspiris Resilia Aortic Tissue Valve in Africa

0Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : Ghana, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The durability of artificial bioprosthestic or tissue heart valves is limited by structural valve deterioration (SVD) due to long-term calcification especially in young patients and in Africa. A novel bioprosthestic valve, the Resilia Inspiris Aortic Tissue Valve has been developed which, in preclinical studies, has shown reduced calcification thus improving durability. The Inspiris Resilia Aortic Valve is a stented tri-leaflet valve made from bovine pericardial tissue. The tissue is created by treating bovine pericardial tissue with Edwards Integrity Preservation. It incorporates a stable capping anticalcification process, which blocks residual aldehyde groups known to bind with calcium. Tissue preservation with glycerol allows the valve to be stored without a traditional liquid-based solution, such as glutaraldehyde. Therefore, the valve is stored under dry packaging conditions and consequently does not require rinsing prior to implantation. The novel tissue preservation technology significantly improves hemodynamic and anticalcification properties compared with the standard artificial bioprosthestic aortic valve, the Perimount tissue valve. The experience of the implantation of this valve in Africa is limited for there seems to be no published experience of the behaviour of the implantation of this special long lasting bioprosthestic valve in Africa and therefore the purpose of this paper is to share our initial experience of the first successful implantation of this Inspiris Resilia Aortic Valve™ in Ghana, Africa. The implantation was done in a 57-year-old patient who presented with symptomatic moderate to severe aortic valve regurgitation with adequate left ventricular systolic function. He has been followed-up for a year now with well-healed wounds and a transthoracic echocardiography revealing a well-seated valve with no regurgitant flow or paravalvular leak. This is the first report describing the use of the new Inspiris Resilia Aortic valve which has increased durability and does not require anticoagulation in Africa as far as we know.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The First Implantation of the Novel Biological Heart Valve, the Inspiris Resilia Aortic Tissue Valve in Africa
Date Crossref
01/01/2020
Éditeur
Science Publishing Group
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsInfective Endocarditis Diagnosis and ManagementMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.