The study on the 20 inch PMT flasher signal
Rattachement africain : cn, de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
20-inch PMTs are widely used in large-scale neutrino experiments because of their high light coverage and high detection efficiency. If there is a flasher around or inside a PMT, this will damage the PMT and potentially affect other PMTs. Therefore it's necessary to research the flasher. The flasher is caused by a discharge on the sharp edge inside the PMT or the voltage divider. In this experiment, the flasher inside the PMT is researched, and the part caused from the voltage divider is excluded by applying light shielding. This paper describes three different trigger modes: self-trigger, mutual-trigger, and external-trigger mode. These are designed to measure the flasher properties inside the 20-inch Dynode-PMT and MCP-PMT.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- The study on the 20 inch PMT flasher signal
- Date Crossref
- 15/06/2020
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.