SPATIAL DISTRIBUTION OF INDOOR CONCENTRATIONS OF GREENHOUSE GASES AND AMMONIA IN A NATURALLY VENTILATED DAIRY BUILDING

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Livestock buildings are a main source of gaseous emissions, such as ammonia (NH3), methane (CH4), carbon dioxide (CO2), and nitrous oxide (N2O). Determination of spatial distribution of indoor gaseous concentrations is a particularly difficult task. Therefore, this study aims is investigation indoor concentrations of NH3, CH4, CO2, and N2O and analyzing their spatial distribution. Continuous measurements of indoor gaseous concentrations were carried out in a naturally ventilated dairy building. Ventilation rates were estimated and emission rates were quantified. Consequently, the results were compared with each other by performing correlation and regression analysis to develop the functions that estimate relationships among these gases. A multiple t-test was conducted for all gases to detect whether the indoor concentrations at different measuring points vary significantly from each other. Sensitivity analysis was conducted to assess the influence of the uncertainty of individual assumptions on the overall results of ventilation and emission rates. The results illustrated that spatial distribution of indoor gaseous concentrations is not uniform, where concentrations at the leeward side of the building were significantly higher than the concentrations at the windward side. The emissions factors were 1.8, 10.2, 351, and 0.1 g h-1 AU-1 for NH3, CH4, CO2, and N2O, respectively.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
SPATIAL DISTRIBUTION OF INDOOR CONCENTRATIONS OF GREENHOUSE GASES AND AMMONIA IN A NATURALLY VENTILATED DAIRY BUILDING
Date Crossref
01/04/2018
Éditeur
Egypts Presidential Specialized Council for Education and Scientific Research
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Odor and Emission Control TechnologiesIndoor Air Quality and Microbial Exposure

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.