Aller au contenu principal
2008 article

Clinical application of positron emission tomography with Pittsburgh compound B in the early diagnosis of Alzheimer's disease

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : ph. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Objective To evaluate the roles of positron emission tomography (PET) with N-methyl [11C]2-(4' -methylaminophenyi-6-hydroxybenzathiazole) (11C-PIB) in the early diagnosis of Alzheimer's disease (AD).Methods Six AD patients,7 mild cognitive impairment (MCI) patients and 6 normal controls (NC) were diagnosed and assessed with brain PET with 11C-PIB.The emission images obtained at 5,25 and 45 min after 11C-PIB administration were analysed.Results Using visual analysis to summarize the characteristics of the imagings of each group: comparing to NC,the AD patients show high 11C -PIB up take,and low clearance rate of 11C-PIB at 45 min.The imagings of MCI group show heterogeneous,overlapping with AD and NC group.The statistical analysis shows: in AD group,the standard uptake value (SUV) ratio of parietal lobe,frontal lobe,temporal lobe,occipital lobe and hippocampal at 45 min was 1.91±0.21,2.09±0.41,1.92±0.35,1.66±0.41,1.55±0.28 respectively,and were higher than that of NC group (value being 1.48±0.53,1.57±0.64,1.36±0.53,1.27±0.40,1.17±0.33) with statistical significance,t=8.114,5.620,5.705,3.650 and 2.866,P=0.0001,0.0002,0.0002,0.0045 and 0.0170 respectively.In MCI group,the SUV ratio of parietal lobe,frontal lobe,temporal lobe,occipital lobe and hippocampal at 45 min was 1.48 ± 0.53,1.57 ± 0.64,1.36±0.53,1.27 ± 0.40,1.17±0.33 respectively,and were higher than that of NC group,but there was no statistical significance.Conclusion 11C-PIB PET imaging can differentiate AD patients from normal and anticipate the transformation of MCI patients. Key words: Alzheimer disease;  Cognition disorders;  Thiazoles;  Aniline compounds;  Positron-emission tomography

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Où se fait cette recherche

  • Chinese General Hospital College of Nursing and Liberal Arts pays non établi dans la notice
    Établissement de santé
  • General Hospital of PLA Department of Geriatric NeuroLogy pays non établi dans la notice
    Établissement de santé

Chinese General Hospital College of Nursing and Liberal Arts et Department of Geriatric NeuroLogy — General Hospital of PLA.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Imaging Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.