Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging

10Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for inoperable, intermediate- or high-risk patients with severe symptomatic aortic stenosis and has been associated with excellent clinical outcomes. A clinically relevant remaining problem is aortic regurgitation (AR) post-TAVI, which is associated with increased mortality. Therefore, we conducted a prospective randomised trial to assess the safety and efficacy of a first-generation self-expandable valve (SEV; CoreValve) and a third-generation balloon-expandable valve (BEV; Sapien 3) with respect to clinical outcomes and AR as determined quantitatively by magnetic resonance imaging (MRI). METHODS: The ELECT study was an investigator-initiated, single-centre trial involving patients with severe symptomatic aortic stenosis and with a clinical indication for transfemoral TAVI. Fifty-six patients were randomly assigned to the BEV or SEV group. RESULTS: AR determined quantitatively by MRI was lower in the BEV than in the SEV group [regurgitant fraction: 1.1% (0-8.0) vs 8.7% (3.0-14.8) for SEV; p = 0.01]. Secondary endpoints according to the criteria of the Second Valve Academic Research Consortium (VARC-2) showed BEV to have better early safety [0 (0%) vs 8 (30%); p = 0.002] at 30 days and a lower risk of stroke [0 (0%) vs 5 (21%); p = 0.01], major adverse cardiac and cerebrovascular events [0 (0%) vs 10 (38%); p < 0.001] or death [0 (0%) vs 5 (19%); p = 0.02] in the 1st year compared with SEV. CONCLUSIONS: The use of the latest generation of BEV was associated with less AR as quantitatively assessed by MRI. Although the use of MRI to quantify AR is not feasible in daily clinical practice, it should be considered as a surrogate endpoint for clinical outcomes in comparative studies of valves for TAVI. ClinicalTrials.gov number NCT01982032.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging
Date Crossref
03/04/2020
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesCardiovascular Function and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.