Aller au contenu principal
Accès ouvert déclaré 2020 article

Hemostatic efficacy of an advanced bipolar sealer in open gynecologic, thoracic, and colectomy procedures: A prospective cohort study

6Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

ABSTRACT Background: An advanced bipolar (ABP) tissue sealer designed for division of major vessels in open procedures was evaluated in a prospective post-market study. The objective was to provide clinical data for assessment of vessel transection, hemostatic performance and ease of use of the ABP device during open colectomy, gynecologic, and thoracic operations. Materials and methods: The ABP test device was used in colectomy (n = 36), gynecologic (n = 44), and thoracic (n = 21) procedure groups. Vessels transected with the ABP device were graded intraoperatively on a hemostasis scale of 1–4, defined as follows: Grade1, no bleeding; Grade 2, minor bleeding with no intervention; Grade 3, minor bleeding requiring touchup with the test device or monopolar cautery; and Grade 4, significant bleeding requiring intervention with any additional hemostatic product. The primary performance measure was the percentage of vessels that achieved hemostasis grades ≤3. The primary safety endpoint was the summarization of all ABP device-related adverse events (AEs). Results: For all three procedure groups together, 302 (96.2%) of 314 total vessel transections were scored as hemostasis grades ≤ 3, including 270 (86.0%) that were rated Grade 1. Twelve transections (3.8%) were Grade 4, which included 9 vessels transected in the gynecologic group and 3 in the thoracic group. Three subjects experienced a total of 4 device-related AEs, consisting of hematoma, hypotension, procedural pain, and superficial thermal burn. All 4 device-related AEs were mild in severity. Conclusion: The advanced bipolar device exhibited effective hemostasis, an acceptable safety profile, and ease of use during colectomy, thoracic, and gynecologic procedures. Trial registry number: ClinicalTrials.gov, NCT034411. Highlights:

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Hemostatic efficacy of an advanced bipolar sealer in open gynecologic, thoracic, and colectomy procedures: A prospective cohort study
Date Crossref
01/01/2020
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Thyroid and Parathyroid SurgeryHemostasis and retained surgical itemsEsophageal and GI Pathology

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.