Relationship Between Contact Lens Sensor Output Parameters and Visual Field Progression in Open-angle Glaucoma: Assessment of a Practical Tool to Guide Clinical Risk-assessment
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: In recent years, new technologies have emerged to better analyze and interpret intraocular pressure (IOP) fluctuations. Among them is the progression report (PR), an algorithm based on continuous contact lens sensor (CLS) readings to estimate the likelihood of fast visual field (VF) glaucomatous progression. The objective of this study is to validate the PR. METHODS: In this retrospective study, 30 open-angle glaucoma patients were enrolled. Twenty-four hours IOP-related variations were recorded using a CLS. Recordings were used to generate PR. The likelihood of fast VF progression (<-1 dB/y mean deviation) was estimated by 2 masked assessors based on clinical parameters. At least 3 VF were performed over the 2 years following the initial assessment, to determine actual progression. RESULTS: Mean age was 65.9±10.45 years, with a mean baseline mean deviation of -5.4±5.1. After a mean follow-up of 29.5±12.9 months, 26.7% of eyes were assessed as fast progressors (-2.9±1.9 dBs/y). The average risk-score attributed by the PR was 42% [41% (slow) vs. 44% (fast); P=0.035]. Correlations between the 2 assessors were good (r=0.59), and identical to that between PR and the averaged assessors' gradings. Correlations between mean deviation progression rates and PR, Assessor 1 and Assessor 2's gradings were, r=0.57, 0.31, and 0.43, respectively. CONCLUSIONS: PR provided comparable predictions of the risk of fast VF progression as did physician estimates based on all available clinical data. With their relationship to the eye's biomechanical properties and the ocular tissues' response to pressure variations, CLS recordings may offer new information that complements conventional examinations.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Relationship Between Contact Lens Sensor Output Parameters and Visual Field Progression in Open-angle Glaucoma: Assessment of a Practical Tool to Guide Clinical Risk-assessment
- Date Crossref
- 27/03/2020
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Colorado Denver pays non établi dans la noticeUniversité ou école supérieure
-
Glaucoma Research Center pays non établi dans la noticeStructure de recherche
-
University of Colorado School of Medicine Department of Ophthalmology pays non établi dans la noticeUniversité ou école supérieure
University of Colorado Denver, Glaucoma Research Center et Department of Ophthalmology — University of Colorado School of Medicine.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.