P964 Assessment of long-term durability of transcatheter implanted aortic valves - structural and nonstructural deteriorations in 5 years follow-up

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Introduction Transcatheter aortic valve implantation (TAVI) is the method of choice for patient with a significant stenosis (AS) who are contraindicated for cardio-surgical procedure. Medium – term results of TAVI are comparable with results observed for surgical replacements. There is limited knowledge of structural, nonstructural and clinical complications in five years follow-up which could contribute to TAVI indication for implantation in young patients. Goal. The aim of this study is to assess structural and non-structural deterioration of TAVI prosthesis by echocardiography and clinical evaluation at 5 years follow-up. Methods By the end of 2013, 112 patients were implanted TAVI in our center( average age, 80,4 ± 7,2 y, 53(47% ) males. All patients underwent both clinical and echocardiographic examination once a year and underwent native CT after five year. We analysed mortality, structural and non- structural deteriorations, and standard echocardiographic parameters before and after implantation, and at 5 years follow-up. Results 5-years mortality was 58%. There was not a statistically significant difference in age between the patients who survive and who died (80,2 ±7,3 vs 80,6 ± 7,3 p = 0.77) ,they had similar logistic EUROSCORE (17,0 ± 12,4 vs 16,9 ± 15,0, p = 0,96) and EF 53,8 ± 11,1 vs 52,3 ± 11,7,p= 0,51) before the procedure. 48 patients underwent the five years follow –up. Only one patient had to undergo reTAVI due to the earlier prosthetic degeneration. The average EOA was 1,88 ± 0,33 cm2), the average V max. after five years was 1,8 ± 0,4 m/s, PG max 13,6 ± 6,2 mm Hg a PG mean 8 ± 3,6 mm Hg ( no significant increase in time),Post procedural paravalvular regurgitation ≥ 2/4 appeared in 14 % patients. Twenty –three patients underwent CT scan which resulted in Agaston score O on TAVI replacement in 19(83 %) patients. Conclusion After 5 years follow-up, low rates of structural and nonstructural deterioration after TAVI were noted, suggesting good long- term durability.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
P964 Assessment of long-term durability of transcatheter implanted aortic valves - structural and nonstructural deteriorations in 5 years follow-up
Date Crossref
01/01/2020
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Valve Diseases and TreatmentsInfective Endocarditis Diagnosis and Management

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.