Gamma and Proton Irradiation Tests on a Piezoelectric Actuator
Rattachement africain : ch, es. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Piezoelectric actuators are candidates for use in radioactive environments but specific radiation tests are necessary to understand the radiation effects on the whole actuator assembly. The results of three irradiation tests on a piezoelectric actuator used for Crystal Collimation are presented. The total ionising dose effects are studied with two Gamma (60Co) Tests up to 10 MGy and 1 MGy, whereas the displacement damage effects are studied in a Proton Test up to 2 MGy and 1.14 × 1016p/cm2fluence. The main results are summarised for each test, presenting a maximum impedance increase of less than 25% (Proton Test), a maximum free stroke reduction of less than 25% (Proton Test) and a variation in the shape of the hysteresis response of the actuator.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Gamma and Proton Irradiation Tests on a Piezoelectric Actuator
- Date Crossref
- 01/01/2019
- Éditeur
- Institute of Electrical and Electronics Engineers (IEEE)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.