Aller au contenu principal
Accès ouvert déclaré 2020 article

Hyperspectral imaging for noninvasive tissue perfusion measurements of the lower leg: review of literature and introduction of a standardized measurement protocol with a portable system

11Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: Hyperspectral imaging (HSI) is a noninvasive technique for transcutaneous measurements of tissue perfusion. This study (1) provides a review of the current literature on HSI for tissue perfusion measurements of the lower leg and (2) introduces a standardized measurement protocol for HSI measurements with a portable system. EVIDENCE ACQUISITION: A literature search was performed for studies on tissue perfusion measurements with HSI in the lower extremity. A standardized protocol was developed to perform HSI measurements in 43 healthy volunteers at the plantar side of the foot and at the lateral side of the calf, with 3 consecutive hyperspectral images at each location. EVIDENCE SYNTHESIS: The literature review identified 9 studies, including 2 of healthy volunteers, 4 of patients with diabetes mellitus, and 3 of patients with peripheral arterial disease. In 5 of 7 patient studies, HSI values were associated with severity of disease or wound healing. In our study, the healthy volunteers' HSI values for oxyhemoglobin, deoxyhemoglobin, and oxygen saturation were (mean±SD) 82.8±24, 55.7±15.7, and 59.2±11.7, respectively, at the plantar surface of the foot, and 40.8±11, 38.0±7.8, and 51.7±10.5, respectively, at the lateral side of the calf. HSI values differed significantly between the calf and plantar locations. Intraoperator reliability between the 3 consecutive images ranged from 81% to 89%. CONCLUSIONS: Limited evidence indicates that HSI is associated with severity of peripheral arterial disease and diabetes mellitus, and with wound healing. Hyperspectral images with a portable system can be taken with high precision when a standardized measurement protocol is used. However, differences exist at several locations at the lower extremity, so each measurement location should be used as its own reference when consecutive measurements are performed during follow-up. More studies with larger patient cohorts should be performed before HSI can be incorporated as standard tool in the diagnostic armamentarium of the vascular specialist.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Hyperspectral imaging for noninvasive tissue perfusion measurements of the lower leg: review of literature and introduction of a standardized measurement protocol with a portable system
Date Crossref
01/01/2020
Éditeur
Edizioni Minerva Medica
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Optical Imaging and Spectroscopy TechniquesInfrared Thermography in MedicinePeripheral Artery Disease Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.