The correlation of CBCT analysis derived bone density parameters with primary implant stability - a clinical study

2Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : me. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background/Aim. There are numerous studies on the usefulness of computed tomography (CT) in the assessment of the bone volume and morphology and on the relationship between CT and primary implant stability. But there is the scarcity of data about the correlation between bone density and the value of primary implant stability. The aim of this study was to examine the correlation of cone beam CT (CBCT) analysis derived bone density with primary stability value. Methods. Clinical prospective experimental study was conducted on 38 healthy patients missing one tooth in the lateral region. It was planned to install Bredent Blue Sky Narrow self-taping dental implants with dimensions 3.5 ? 10 mm. During preoperative preparation, a CBCT scan was performed on Planmeca apparatus, followed by preimplantation measurements and planning in the CBCT apparatus software (Romexis). The mean value of the average bone density was automatically generated and expressed in Hounsfield units (HU). Upon implant placement, we performed measurements of the primary implant stability using Osstell apparatus. Results. Of the 38 patients included in the study, there were 68.4% male patients and 31.6% female patients. The arithmetic mean of the measured bone density of all subjects in the study amounted to 536.2 HU. The arithmetic mean of dental implant primary stability for all subjects in the study was 68.7 ISQ. There was a statistically significant strong positive connection between HU and ISQ (r = 0.744, p < 0.001). Higher HU values were connected to higher ISQ values. In the multivariate linear regression model, statistically significant predictors of higher ISQ values: males (B = 4.669; p = 0.047) and higher HU values (B = 0.032; p < 0.001). Conclusion. In our clinical study, there was a statistically significant strong positive correlation between the bone density expressed in HU units, measured in the software of the CBCT device and the primary stability of dental implants expressed in ISQ units.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The correlation of CBCT analysis derived bone density parameters with primary implant stability - a clinical study
Date Crossref
01/01/2021
Éditeur
National Library of Serbia
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Dental Implant Techniques and OutcomesDental Radiography and ImagingPeriodontal Regeneration and Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.