P1669Frequency and patterns of implantable cardiac defibrillator therapies in patients with ventricular assist devices
Résumé fourni par la source
Abstract Purpose Durable ventricular assist devices (VADs) use is a life-saving therapy in patients with end-stage heart failure. These patients are at high risk for ventricular arrhythmias. The pattern of ICD therapies in these patients is not well characterized. Methods Our single-center retrospective cohort included 86 patients with ICDs and VADs followed at our Centre. Data collected included frequency of ICD therapies, type of therapy (appropriate vs. inappropriate; shocks vs. anti-tachycardia pacing (ATP)), and time-course of therapies. Results 36 patients (42%) received ICD therapy during a mean follow-up period of 13.6 months. There were 105 episodes (2.9 episodes/patient) during which ICD therapies were delivered, with a total of 379 individual arrhythmias treated (3.6 arrhythmias per episode of therapy). 61.4% of therapies were appropriate, 8.4% were inappropriate, and 31.6% were unknown. Of the 79 episodes treated with appropriate therapy, 36 episodes (46%) required ICD shocks, whereas 43 episodes (54%) were treated with ATP alone. Overall, 33% of the total cohort and 81% of patients who received therapy received at least one ICD shock. Twenty-two patients (61%) received therapy between 1–3 times, while the remainder (14 patients, 39%) received therapy 3–10 times. Eighteen (17%) episodes occurred within the first month after LVAD implantation, with 10 (10%) occurring between 1–3 months, 53 (50%) occurring between 3–12 months, and 24 (23%) occurring more than one year after VAD implantation. Conclusion Analysis of our VAD cohort revealed three important findings: 1. ICD therapy is very common (42%) in the first year especially after LVAD implantation; 2. Ventricular arrhythmias are highly clustered in this cohort; 3. ATP is frequently effective. These findings have important implications on device follow-up and programming for this expanding patient population.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- P1669Frequency and patterns of implantable cardiac defibrillator therapies in patients with ventricular assist devices
- Date Crossref
- 01/10/2019
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.