2019 article

P2791Method for detection of blood clots in ventricular assist devices

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : se. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background The technical development of modern ventricular assist devices (VAD) shows continued improvement in patient outcome. VADs continue to gain increased use not only as bridge to transplant but also as a destination therapy. However, VAD therapy is associated with complications, among which thromboembolic complications are common. Better management for early detection is paramount to improve patient outcome. Purpose The aims of this study were to determine if the VADs under consideration may retain clots, and to assess the feasibility of early clot detection using a non-invasive technique. Methods Two different VADs, the HeartMate II (HMII) and HeartMate 3 (HM3) were tested in a mock loop. Clot analogs (2 cm yarn fragments) were introduced into the loop upstream to the pump. Sound and vibration of the pump was measured using two hydrophones and at the inflow and outflow of the VAD (frequency range: 0.1Hz to 180kHz). The acoustic/vibration data was analyzed concerning the spectral content. Results The flow at the outflow section contained a low frequency swirling component. This appeared to be the basic flow feature. However, in the presence of clot analogs, the frequency signal was amplified. For the HMII this occurred below 10Hz. Concerning the HM3 this signal was more difficult to analyze due to HM3's non-constant rotational speed. However, by using wavelet filtering, it was possible to detect the low frequency signal in the presence of clot analogs. It was also observed that clot analogs tended to accumulate at certain regions in the respective VAD. In the HM3, clot fragments remained in a stagnation region at the bottom pump. This experimental finding contradicts published washout results based on a passive scalar model. Conclusions These mock loop results indicated the feasibility of early detection of blood clots in VADs by analysis of the sound/vibration induced by the clot. The signal “finger-print” needed for detection may also be possible to recover under non-continuous operational rotational speed as in the HM 3.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
P2791Method for detection of blood clots in ventricular assist devices
Date Crossref
01/10/2019
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Mechanical Circulatory Support DevicesAdvanced Sensor and Energy Harvesting MaterialsFuel Cells and Related Materials

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.