High voltage calibration method for the CMS RPC detector
R. Reyes-Almanza, A. Dimitrov, A. Fagot, M. Gul, C. Roskas, M. Tytgat, N. Zaganidis, S. Fonseca De Souza, A. Santoro, F. Torres Da Silva De Araujo, А. Александров, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. Qian, Di-Fan Yi, C. Ávila, A. Cabrera, M. Segura, S. Aly, Y. Assran, A. Mahrous, A. Mohamed, C. Combaret, M. Gouzevitch, G. Grenier, F. Lagarde, I. B. Laktineh, H. Mathez, L. Mirabito, K. Shchablo, I. Bagaturia, D. Lomidze, I. Lomidze, L. M. Pant, V. Bhatnagar, R. Gupta, R. Kumari, M. Lohan, J. B. Singh, V. Amoozegar, B. Boghrati, H. Ghasemy, Somaye Malmir, M. Mohammadi Najafabadi, M. Abbrescia, A. Gelmi, G. Iaselli, S. Lezki, G. Pugliese, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, S. Buontempo, A. Di Crescenzo, G. Galati, F. Fienga, I. Orso, L. Lista, S. Meola, P. Paolucci, E. Voevodina, A. Braghieri, P. Montagna, M. Ressegotti, C. Riccardi, P. Salvini, P. Vitulo, S.W. Cho, S. Choi, B. Hong, K.S. Lee, Jae Hoon Lim, S. K. Park, J. Goh, T.J. Kim, Salvador Carrillo Moreno, O. Miguel Colin, F. Vazquez Valencia, S. Carpinteyro Bernardino, J. Eysermans, I. Pedraza, C. Uribe Estrada, M.C. Duran-Osuna, M. Ramirez-García, G. Ramirez-Sanchez, A. Sánchez-Hernández, R. I. Rabadán Trejo, H. Castilla-Valdez, A. Radi, H. R. Hoorani, S. Muhammad, M. A. Shah, I. Crotty
2Citations signalées — pas une note de qualité
32Institutions déclarées
16Pays d’affiliation déclarés
Résumé fourni par la source
The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- High voltage calibration method for the CMS RPC detector
- Date Crossref
- 30/09/2019
- Éditeur
- IOP Publishing
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.
Sujets associés
Particle Detector Development and PerformanceParticle physics theoretical and experimental studiesRadiation Detection and Scintillator Technologies