Endosonographic evaluation of the mediastinum through the i-gel O 2 supraglottic airway device

5Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction: Endobronchial ultrasound (EBUS) is an endoscopic diagnostic procedure combining flexible fibrobronchoscopy with ultrasound techniques; it allows transbronchial needle aspiration biopsy for the diagnosis and staging of mediastinal masses. We present our preliminary experience with the use of the i-gel O 2 supraglottic airway device for management of EBUS procedures. Methods: An observational study on 39 patients who underwent EBUS under general anesthesia was performed. Airways were managed with i-gel O 2 by anesthesiologists unfamiliar with it. Data collected included patient characteristics, i-gel O 2 positioning, mechanical ventilation, procedure, and complications occurring during and after the EBUS. Results: The i-gel airway was successfully positioned during the first attempt in 34/39 cases (87.2%). No failed positioning was recorded. The EBUS scope easily passed through the i-gel in all patients and in 14 (35.6%) cases it was also inserted through the esophagus allowing the examination or fine needle aspiration of paraesophageal lymph nodes. In one case, during the EBUS procedure, the i-gel was dislocated but easily put in place again. During EBUS, air leakages were significant in 2 cases (5.1%) and minimal in 14 cases (35.9%). A brief self-solved laryngospasm and a bronchospasm during bronchoscopy were recorded. After recovery, no patients had dysphagia; mild odynophagia and pharyngodinia were referred by 2 (5.1%) and 12 (30.1%) patients, respectively. Conclusions: The i-gel O 2 airway is easy to position and manage even for anesthesiologists unfamiliar with it. This supraglottic airway device is suitable for a complete endosonographic evaluation of the mediastinum.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Endosonographic evaluation of the mediastinum through the i-gel O <sub>2</sub> supraglottic airway device
Date Crossref
28/08/2019
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Airway Management and Intubation TechniquesTracheal and airway disordersForeign Body Medical Cases

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.