Short-Term Double Layer Mesh Stent Patency for Emergent or Elective Carotid Artery Stenting

21Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : nl, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background and Purpose- Novel double layer micromesh stents have recently been introduced for treatment of patients with significant carotid stenosis. Strict evaluation of safety and patency of such novel devices is required both in elective and in emergency interventions. We report a single center experience with double layer mesh stents for carotid artery revascularization. Methods- Consecutive patients who underwent carotid artery stenting with a double layer mesh stent between June 2015 and September 2018 in our tertiary vascular referral center were included. Treatment indications were emergent carotid artery stenting for intracranial or extracranial carotid stenosis in patients undergoing intraarterial thrombectomy for acute ischemic stroke in the anterior circulation, or elective carotid artery stenting for significant symptomatic or asymptomatic stenosis. End points were postprocedural thrombotic stent occlusion and procedural stroke or death. Results- Fifty-four patients were included; 27 were treated for acute stroke with intracranial and extracranial (tandem) lesions and 27 for elective stenting. Follow-up imaging was available for 9/27 (33%) patients with acute stroke, and 19/27 (70%) electively treated patients. Five stent occlusions occurred, of which 2 were symptomatic with clinical deterioration within one day. Another patient deteriorated on postprocedural day one, but imaging of the carotids was not performed, and the stent turned out occluded on the 30-day duplex. All stent occlusions occurred in patients treated for acute stroke. Conclusions- This study suggests that occlusion of novel double layer mesh stents occurs in a considerable proportion of carotid artery stenting procedures performed in the emergency setting for acute stroke, with occlusion-related symptoms in half the cases. Future prospective studies should clarify the role of double layer mesh stents in this high-risk patient population.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Short-Term Double Layer Mesh Stent Patency for Emergent or Elective Carotid Artery Stenting
Date Crossref
01/07/2019
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cerebrovascular and Carotid Artery DiseasesAcute Ischemic Stroke ManagementIntracranial Aneurysms: Treatment and Complications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.