Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi
Rattachement africain : us, Malawi, ca. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: The study was conducted in a remote sputum sample collection sites and GeneXpert® MTB/RIF testing centers to detect Mycobacterium tuberculosis in Malawi. The main purpose of the study was to evaluate whether sputum samples stored and transported with OMNIgene®•SPUTUM (OM-S) medium perform comparably to the routine cold-chain stored and transported samples for GeneXpert testing to detect Mycobacterium tuberculosis. METHODS: Two sputum samples from each of 362 tuberculosis suspects were randomly assigned to the OMNIgene treated (OM-S group) or the standard-of-care group (SOC; transported via cold chain). All specimens were tested at regional GeneXpert testing sites using the expectorated (raw) sputum protocol. Demographic, clinical, transport/storage and Xpert data were recorded for each specimen pair. Agreement between the SOC and OM-S groups' Xpert results was evaluated using Cohen's kappa analysis. RESULTS: Mean patient age was 42.3 years (range 2-79 years), 77% of patients were female, and 80% were HIV-positive. Mean transport/storage time was 6.7 days (range, 0-29 days). The rates of MTB positivity for the OM-S and SOC groups were comparable (11.8 and 11.2%, respectively), inter-test agreement was "very good" (κ = 0.97), and overall percent agreement was 99%. Two specimen pairs (both mucoid, one 13 days transport, one 1 day transport) had discordant Xpert results. CONCLUSION: OM-S-treated sputum specimens can undergo multi-day ambient-temperature storage as well as transport and yield Xpert results comparable to those of cold-chain-transported samples in Malawi.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi
- Date Crossref
- 16/05/2019
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.