Aller au contenu principal
Accès ouvert déclaré 2019 article

Volumetric and End-Tidal Capnography for the Detection of Cardiac Output Changes in Mechanically Ventilated Patients Early after Open Heart Surgery

6Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : no. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background. Exhaled carbon dioxide (CO2) reflects cardiac output (CO) provided stable ventilation and metabolism. Detecting CO changes may help distinguish hypovolemia or cardiac dysfunction from other causes of haemodynamic instability. We investigated whether CO2 measured as end-tidal concentration (EtCO2) and eliminated volume per breath (VtCO2) reflect sudden changes in cardiac output (CO). Methods. We measured changes in CO, VtCO2, and EtCO2 during right ventricular pacing and passive leg raise in 33 ventilated patients after open heart surgery. CO was measured with oesophageal Doppler. Results. During right ventricular pacing, CO was reduced by 21% (CI 18–24; p<0.001 ), VtCO2 by 11% (CI 7.9–13; p<0.001 ), and EtCO2 by 4.9% (CI 3.6–6.1; p<0.001 ). During passive leg raise, CO increased by 21% (CI 17–24; p<0.001 ), VtCO2 by 10% (CI 7.8–12; p<0.001 ), and EtCO2 by 4.2% (CI 3.2–5.1; p<0.001 ). Changes in VtCO2 were significantly larger than changes in EtCO2 (ventricular pacing: 11% vs. 4.9% ( p<0.001 ); passive leg raise: 10% vs. 4.2% ( p<0.001 )). Relative changes in CO correlated with changes in VtCO2 ( ρ=0.53 ; p=0.002 ) and EtCO2 ( ρ=0.47 ; p=0.006 ) only during reductions in CO. When dichotomising CO changes at 15%, only EtCO2 detected a CO change as judged by area under the receiver operating characteristic curve. Conclusion. VtCO2 and EtCO2 reflected reductions in cardiac output, although correlations were modest. The changes in VtCO2 were larger than the changes in EtCO2, but only EtCO2 detected CO reduction as judged by receiver operating characteristic curves. The predictive ability of EtCO2 in this setting was fair. This trial is registered with NCT02070861 .

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Volumetric and End-Tidal Capnography for the Detection of Cardiac Output Changes in Mechanically Ventilated Patients Early after Open Heart Surgery
Date Crossref
30/05/2019
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hemodynamic Monitoring and TherapyCardiac, Anesthesia and Surgical OutcomesNon-Invasive Vital Sign Monitoring

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.