Plasma and dried blood spot lysosphingolipids for the diagnosis of different sphingolipidoses: a comparative study

95Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : it, au. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background Lysosphingolipids, the N-deacylated forms of sphingolipids, have been identified as potential biomarkers of several sphingolipidoses, such as Gaucher, Fabry, Krabbe and Niemann-Pick diseases and in GM1 and GM2 gangliosidoses. To date, different methods have been developed to measure various lysosphingolipids (LysoSLs) in plasma. Here, we present a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for a simultaneous quantification of LysoSLs (HexSph, LysoGb3, LysoGM1, LysoGM2, LysoSM and LysoSM509) in dried blood spot (DBS). This LC-MS/MS method was used to compare the levels of LysoSLs in DBS and plasma in both affected patients and healthy controls. Methods Lysosphingolipids were extracted from a 3.2 mm diameter DBS with a mixture of methanol:acetonitrile:water (80:15:5, v/v) containing internal stable isotope standards. Chromatographic separation was performed using a C18 column with a gradient of water and acetonitrile both with 0.1% formic acid in a total run time of 4 min. The compounds were detected in the positive ion mode electrospray ionization (ESI)-MS/MS by multiple reaction monitoring (MRM). Results The method was validated on DBS to demonstrate specificity, linearity, lowest limit of quantification, accuracy and precision. The reference ranges were determined in pediatric and adult populations. The elevated levels of LysoSLs were identified in Gaucher disease (HexSph), Fabry disease (LysoGb3), prosaposin deficiency (HexSph and LysoGb3) and Niemann-Pick disease types A/B and C (LysoSM and LysoSM509). The correlation in the levels between DBS and plasma was excellent for LysoGb3 and HexSph but poor for LysoSM and LysoSM509. Conclusions Despite the fact that plasma LysoSLs determination remains the gold standard, our LC-MS/MS method allows a rapid and reliable quantification of lysosphingolipids in DBS. The method is a useful tool for the diagnosis of different sphingolipidoses except for Niemann-Pick type C.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Plasma and dried blood spot lysosphingolipids for the diagnosis of different sphingolipidoses: a comparative study
Date Crossref
15/05/2019
Éditeur
Walter de Gruyter GmbH
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Lysosomal Storage Disorders ResearchErythrocyte Function and PathophysiologyCellular transport and secretion

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.