Novel Assessment of Tricuspid Valve Annulus and Papillary Muscle Geometry in Systolic and Diastolic Normal Heart Using 3D Printed Right Ventricular Models
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Objective: Three-dimensional (3D) printing models have been demonstrated to be useful in therapeutic guiding. However, there have been few studies exploring the properties of the heart using 3D printed models. We attempted to assess the inadequately understood tricuspid valve annulus (TA) and papillary muscle (PM) geometrical changes in diastole and systole using 3D printed right ventricular models. Methods: Stereolithographic (STL) files were converted, using ECG-gated 320-detector-row multislice computed tomography in order to analyze the geometry of the TA and PM throughout the cardiac cycle. Right ventricular end-diastolic (ED) and end-systolic (ES) models were subsequently 3D printed. Results: Characterizing the shape of the annulus, annular height increased from ED to ES (7.0 to 11.0mm), whereas eccentricity (measure of how circular a shape is) decreased from ED to ES (0.88 to 0.70) showing that the annulus became more oval and wave form in ES. Interpapillary muscle distance (IPMD) was measured from papillary tip-to-tip and base-to-base. Tip-to-tip IPMD between septal and anterior(S-A), anterior and posterior(A-P), septal and posterior(S-P) PM decreased from ED to ES respectively (17.0 to 10.0mm, 16.0 to 14.0mm, and 25.5 to 22.5mm). Similarly, base-to-base IPMD between S-A, A-P, S-P PM decreased from ED to ES (19.5 to 19.0mm, 22.0 to 17.0mm, and 36.5 to 33.0mm). Distance between the septal, the anterior and the posterior PM tip to the apex decreased from ED to ES, suggesting a papillary muscle apical movement (45.0 to 38.0mm, 59.0 to 47.0mm, 66.0 to 55.5mm). Conclusions: The tricuspid valve annulus and papillary muscle geometry were remarkably changed between diastole and systole. These preliminary results support that 3D printing of cardiac models at selected cardiac cycle phase enable accurate assessment of valve complexes.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Novel Assessment of Tricuspid Valve Annulus and Papillary Muscle Geometry in Systolic and Diastolic Normal Heart Using 3D Printed Right Ventricular Models
- Date Crossref
- 01/01/2019
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.