Aller au contenu principal
Accès ouvert déclaré 2019 article

Capsular plication in the non-deformity hip: impact on post-operative joint stability

3Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : ca. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE AND HYPOTHESIS: The aim of this study was to evaluate the hip joint range of motion after different capsular plication. The study hypothesis proposed that capsular plication after hip arthroscopy may reduce hip external rotation and thus prevent the hip joint instability created by arthroscopic capsulotomies. METHODS: Six fresh frozen human cadavers were studied in the intact state (5 males, 1 females) for a total of 12 non-deformity hips tested. They were fixed to the operating room table using a custom-made apparatus. Three Steinman pins were inserted, the first into ASIS, a parallel pin into the distal femur proximal to inter-epicondylar axis and the third pin into the lateral epicondyle. Simulation of arthroscopic capsulotomies was done progressively with simulation of three capsular plication techniques. The first plication technique consisted of a primary plication shift of the antero-lateral capsule. The distal-medial arm of the iliofemoral ligament was shifted toward the proximal-lateral arm. The second plication technique consisted in adding a longitudinal arm to the capsulotomy, between the lateral arm and the medial arm of the iliofemoral ligament, to create a T-shaped capsulotomy. The resulting two triangular capsular flaps were overlaid onto each other by approximately 5 mm, plicated fully and tighly sutured in a double-breast manner. The third plication technique, called redrapping, consisted in excising the inferior capsular triangular flap (previously made in the second technique), and suturing the latero-anterior superior capsular flap to the medial arm of the iliofemoral ligament, superimposing the capsular edges for closure. External rotation of the hip at 0°, 15° and 30° of flexion were obtained after the capsulotomy and each capsular plication technique to quantify the increase in hip stability after plication. Data were assessed using a two-way repeated measure analysis of variance (ANOVAs) and Student's T-test when necessary to determine if the change in external rotation was significantly different. RESULTS: After capsulotomy, external rotation averaged 26.3°, 29.1° and 31.1° at 0°, 15° and 30° of flexion. With the primary plication shift, external rotation averaged 24.9°, 30.3° and 34.0°. With the two-triangle technique, external rotation averaged 26.1°, 31.9° and 33.3°. With the re-draping technique, external rotation averaged 25.8°, 30.9° and 32.0°. A significant relationship was found between «Plication Technique» and «Angle of flexion» factors for the measured angle of external rotation (P = 0.04). A decomposition of the interaction showed that external rotation decreased at 0° of hip flexion and increased as the hip flexion angle increased. The only significant difference found corresponded to the two triangles technique at 15° flexion (mean difference compared to the non-repaired state = 2.8° ± 3.8° or 8.8% increase in external rotation; P = 0.03). CONCLUSIONS: Different techniques of capsular plication result in a non-significant increase in hip external rotation when compared to unrepaired capsulotomies. Therefore, special attention should be paid at the time of capsular plication, which could be disadvantageous when done overzealously aiming to increase postoperative stability.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Capsular plication in the non‐deformity hip: impact on post‐operative joint stability
Date Crossref
01/01/2019
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hip disorders and treatmentsOrthopaedic implants and arthroplastyHip and Femur Fractures

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.