Blood Flow after Endovascular Repair in the Aortic Arch: A Computational Analysis
Rattachement africain : it, nl. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background The benefits of thoracic endovascular aortic repair (TEVAR) have encouraged stent graft deployment more proximally in the aortic arch. This study quantifies the hemodynamic impact of TEVAR in proximal landing zone 2 on the thoracic aorta and the proximal supra-aortic branches. Methods Patients treated with TEVAR in proximal landing zone 2 having available preoperative and 30-day postoperative computer tomography angiography and phase-contrast magnetic resonance imaging data were retrospectively selected. Blood flow was studied using patient-specific computational fluid dynamics simulations. Results Four patients were included. Following TEVAR in proximal landing zone 2, the mean flow in the left common carotid artery (LCCA) increased almost threefold, from 0.21 (0.12–0.41) L/min to 0.61 (0.24–1.08) L/min (+294%). The surface area of the LCCA had not yet increased commensurately and therefore maximum flow velocity in the LCCA increased from 44.9 (27.0–89.3) cm/s to 72.6 (40.8–135.0) cm/s (+62%). One of the patients presented with Type Ib endoleak at 1-year follow-up. The displacement force in this patient measured 32.1 N and was directed dorsocranial, perpendicular to the distal sealing zone. There was a linear correlation between the surface area of the stent graft and the resulting displacement force (p = 0.04). Conclusion TEVAR in proximal landing zone 2 alters blood flow in the supra-aortic branches, resulting in increased flow with high flow velocities in the LCCA. High displacement forces were calculated and related to stent graft migration and Type I endoleak during 1-year follow-up.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Blood Flow after Endovascular Repair in the Aortic Arch: A Computational Analysis
- Date Crossref
- 01/06/2018
- Éditeur
- Georg Thieme Verlag KG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Milan Thoracic Aortic Research Center pays non établi dans la noticeUniversité ou école supérieure
-
University Medical Center Utrecht Department of Vascular Surgery pays non établi dans la noticeÉtablissement de santé
-
IRCCS Policlinico San Donato pays non établi dans la noticeÉtablissement de santé
-
University of Pavia Department of Civil Engineering and Architecture pays non établi dans la noticeUniversité ou école supérieure
-
IRCCS—Policlinico San Donato Department of Radiology pays non établi dans la noticeÉtablissement de santé
Thoracic Aortic Research Center — University of Milan, Department of Vascular Surgery — University Medical Center Utrecht et IRCCS Policlinico San Donato, avec 2 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.