A10383 Towards an Implantable Telemetry System for Photoplethysmography Based Vital Signs Monitoring in Small Animals
Rattachement africain : ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Objectives: Resistant hypertension persists and affects 20% to 30% of all hypertensive patients for which alternative treatment strategies are explored. Increasing attention is given to the sympathetic nervous system (SNS) in the pathogenesis of hypertension. The interruption of the renal SNS by catheter-based denervation has been studied. Another approach may be Baroreflex activation where electrical stimulation of carotid sinus- and aortic arch baroreceptors evokes a reduction in sympathetic neural traffic to the heart, vasculature, kidneys, etc. We have recently reported on ongoing work towards a platform for implantable telemetry devices which includes a versatile Photoplethysmography (PPG) subsystem as well as neuro-stimulation and –recording capabilities. To date, no arterial oxygenation (SpO2) telemetry solution exists for implantation in rodents. Methods: An optical probe is placed during acute animal experiments on the carotid artery of a rat. From the obtained PPG signals, SpO2, heart rate, respiratory cycle, and pulse wave velocity (PWV) are extracted. Also, PPG-based estimation of diastolic blood pressure (DBP) and pulse pressure (PP) is investigated. Results: Our preliminary results confirm that monitoring of arterial oxygenation, heart rate, and respiratory cycle is possible with our setup; further work is required for PWV and thereon based DBP and PP estimation. Conclusion: The interdependence of recorded PPG signals with targeted vital signs was tested in acute in-vivo experiments, yielding encouraging results; sufficient miniaturization for implantation in small animals is feasible. The envisioned device could be an interesting tool in cardiovascular and hypertension research – especially in research on alternative hypertension treatment strategies. The work was partially supported by SNF-NanoTera
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A10383 Towards an Implantable Telemetry System for Photoplethysmography Based Vital Signs Monitoring in Small Animals
- Date Crossref
- 01/10/2018
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Centre Hospitalier Universitaire Vaudois pays non établi dans la noticeÉtablissement de santé
-
École Polytechnique Fédérale de Lausanne pays non établi dans la noticeUniversité ou école supérieure
-
Division of Nephrology & Hypertension University Hospital of Lausanne (CHUV) Switzerland Internal Medicine Branch pays non établi dans la noticeUniversité ou école supérieure
-
Department of Information Technology and Electrical Engineering Swiss Federal Institute of Technology (ETH) Switzerland pays non établi dans la noticeStructure de recherche
Centre Hospitalier Universitaire Vaudois, École Polytechnique Fédérale de Lausanne et Internal Medicine Branch — Division of Nephrology & Hypertension University Hospital of Lausanne (CHUV) Switzerland, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.